Impact of occluder device configurations in in-silico left atrial hemodynamics for the analysis of device-related thrombus
PLOS Computational Biology · 2024
DOI: 10.1371/journal.pcbi.1011546 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS Computational Biology, 2024. Verfasst von Carlos Albors und 5 weiteren Autor:innen. Beteiligte Einrichtung: Physense, BCN Medtech, Department of Information and Communication Technologies, Universitat Pompeu Fabra, 08018 Barcelona, Spain. Hauptthemen laut MEDLINE: Thrombosis, Computer Simulation, Atrial Fibrillation, Hemodynamics. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union’s Horizon 2020, programm GEMINI, GENERALITAAT.
Abstract (Originalsprache)
Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e., size, type, location) remain unstandardized due to the large anatomical variability of the left atrial appendage (LAA) morphology, leading to a 4-6% incidence of device-related thrombus (DRT). In-silico simulations have the potential to assess DRT risk and identify the key factors, such as suboptimal device positioning. This work presents fluid simulation results computed on 20 patient-specific left atrial geometries, analysing different commercially available LAAO occluders, including plug-type and pacifier-type devices. In addition, we explored two distinct device positions: 1) the real post-LAAO intervention configuration derived from follow-up imaging; and 2) one covering the pulmonary ridge if it was not achieved during the implantation (13 out of 20). In total, 33 different configurations were analysed. In-silico indices indicating high risk of DRT (e.g., low blood flow velocities and flow complexity around the device) were combined with particle deposition analysis based on a discrete phase model. The obtained results revealed that covering the pulmonary ridge with the LAAO device may be one of the key factors to prevent DRT, resulting in higher velocities and reduced flow recirculations (e.g., mean velocities of 0.183 ± 0.12 m/s and 0.236 ± 0.16 m/s for uncovered versus covered positions in DRT patients). Moreover, disk-based devices exhibited enhanced adaptability to various LAA morphologies and, generally, demonstrated a lower risk of abnormal events after LAAO implantation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Physense, BCN Medtech, Department of Information and Communication Technologies, Universitat Pompeu Fabra, 08018 Barcelona, Spain.
- IHU Liryc, CHU Bordeaux, Université Bordeaux, Inserm, Pessac, France.
ORCID-Profile: Carlos Albors, Andy L Olivares, Oscar Camara
Förderung
- European Union’s Horizon 2020
- programm GEMINI
- GENERALITAAT
- SimCardioTest: H2020 research and innovation programm
- Spanish Ministry of Science, Innovation and Universities under the GENERALITAAT
Zitieren
APA
Albors, C., Mill, J., Olivares, A. L., Iriart, X., Cochet, H., & Camara, O. (2024). Impact of occluder device configurations in in-silico left atrial hemodynamics for the analysis of device-related thrombus. PLOS Computational Biology. https://doi.org/10.1371/journal.pcbi.1011546
Vancouver
Albors C, Mill J, Olivares AL, Iriart X, Cochet H, Camara O. Impact of occluder device configurations in in-silico left atrial hemodynamics for the analysis of device-related thrombus. PLOS Computational Biology. 2024. doi:10.1371/journal.pcbi.1011546
BibTeX
@article{Albors2024,
author = {Albors, Carlos and Mill, Jordi and Olivares, Andy L and Iriart, Xavier and Cochet, Hubert and Camara, Oscar},
title = {Impact of occluder device configurations in in-silico left atrial hemodynamics for the analysis of device-related thrombus},
journal = {PLOS Computational Biology},
year = {2024},
doi = {10.1371/journal.pcbi.1011546}
}
EUVIMED