Diagnostic Performance of General Practitioners in Carotid Plaque Detection Using AI-Enhanced Point-of-Care Ultrasound After Systematic Training
The Annals of Family Medicine · 2026-05 · 24 (3) · 205-210
DOI: 10.1370/afm.250351 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Annals of Family Medicine, online erschienen am 26.05.2026. Verfasst von Xiaochuan Liu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Practice, Zhongshan Hospital, Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Point-of-Care Systems, General Practitioners, Plaque, Atherosclerotic, Ultrasonography, Carotid Arteries. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
PURPOSE While point-of-care ultrasound (POCUS) has been integrated into daily practice by general practitioners (GPs) in some countries, there is a paucity of literature documenting its use by Chinese GPs. Additionally, artificial intelligence (AI)-assisted diagnosis is increasingly applied to imaging equipment. This study aims to explore the diagnostic performance of GPs in carotid plaque detection using AI-enhanced POCUS after systematic training. METHODS This diagnostic accuracy trial was conducted in Shanghai, where 7 GPs received systematic training then recruited patients with high atherosclerotic cardiovascular disease risk during outpatient visits for free carotid plaque screening. We comprehensively evaluated their diagnostic performance using 2 approaches: per-patient (ie, assessed whether patients had any carotid plaque) and per-vessel (ie, determined plaque presence in any carotid vessel). Evaluation metrics included sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and the κ statistic for agreement. RESULTS A total of 169 patients (mean age 69.6 years [SD 5.76]; 37.9% male) were included in this study. At the per-patient level, sensitivity was 0.87 (95% CI, 0.80-0.95); specificity was 0.91 (95% CI, 0.86-0.97); PPV was 0.89 (95% CI, 0.82-0.96); NPV was 0.89 (95% CI, 0.83-0.96); and the κ value was 0.78 (95% CI, 0.69-0.88), indicating high agreement with the gold standard. The diagnostic performance evaluated at the per-vessel level was comparable to that at the per-patient level. CONCLUSION Our findings indicate that, after systematic training, GPs can effectively perform carotid plaque screening using AI-enhanced POCUS within a clinical workflow in high-risk elderly populations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of General Practice, Zhongshan Hospital, Fudan University, Shanghai, China.
- Department of General Practice, Wujing Community Health Service Center, Shanghai, China.
- Department of General Practice, Zhongshan Hospital, Fudan University, Shanghai, China yokieyoung@hotmail.com zhigang_pan@163.com.
Zitieren
APA
Liu, X., Yao, S., Yang, H., & Pan, Z. (2026). Diagnostic Performance of General Practitioners in Carotid Plaque Detection Using AI-Enhanced Point-of-Care Ultrasound After Systematic Training. The Annals of Family Medicine, 24(3), 205-210. https://doi.org/10.1370/afm.250351
Vancouver
Liu X, Yao S, Yang H, Pan Z. Diagnostic Performance of General Practitioners in Carotid Plaque Detection Using AI-Enhanced Point-of-Care Ultrasound After Systematic Training. The Annals of Family Medicine. 2026;24(3):205-210. doi:10.1370/afm.250351
BibTeX
@article{Liu2026,
author = {Liu, Xiaochuan and Yao, Sichen and Yang, Hua and Pan, Zhigang},
title = {Diagnostic Performance of General Practitioners in Carotid Plaque Detection Using AI-Enhanced Point-of-Care Ultrasound After Systematic Training},
journal = {The Annals of Family Medicine},
year = {2026},
volume = {24},
number = {3},
pages = {205--210},
doi = {10.1370/afm.250351}
}