EUVIMEDEUVIMED entdecken
Crossref

Submillimeter non-line-of-sight ranging and imaging via cost-effective FMCW interferometry

Huan Liang, Lingchuan Wei, Taotao Qin, Lianfa Bai, Yingjie Shi, Enlai Guo, Jing Han

Photonics Research · 01.07.2026 · 14 (7) · 3005

DOI: 10.1364/prj.595776 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Photonics Research, online erschienen am 23.06.2026. Verfasst von Huan Liang und 6 weiteren Autor:innen. Die Arbeit nennt 73 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Non-line-of-sight (NLOS) imaging technology reconstructs the spatial structure of hidden objects by analyzing scattered light field information. However, existing methods primarily rely on time-of-flight (ToF) measurements, which are limited by imaging resolution and environmental robustness. Here, we propose a submillimeter NLOS ranging and imaging method based on cost-effective frequency-modulated continuous wave (FMCW) interferometry. By deriving a beat signal model for NLOS scenarios, we design a dual-path interferometric system incorporating a Mach–Zehnder calibration optical path constructed with polarization-maintaining optical delay fiber (PM-ODF). A transformation model is established to convert beat signals from the time domain to the transform domain, followed by the development of a dynamic temporal phase subdivision (DTPS) algorithm. This algorithm utilizes the fixed calibration optical path, rather than an optical frequency comb, to monitor the instantaneous frequency of the swept-frequency laser in real-time and compensate for the sweep nonlinearity effect at arbitrary detection distances. Our method achieves a temporal resolution of approximately 1.8 ps over an all-optical fiber link, approaching the theoretical limit determined by the 546 GHz sweep bandwidth. In free space conditions, we demonstrate NLOS ranging and 3D imaging with a ranging resolution of 450 μm and a ranging error of 23 μm, an axial imaging resolving capability of 1 mm with an imaging error of 0.26 mm, a lateral imaging resolving capability of 2.4 mm, and a non-visible imaging distance of 110 cm, which is consistent with theoretical predictions. We demonstrate the capability for high-fidelity reconstruction under intense ambient illumination conditions exceeding 8.0 klux. Notably, our method maintains accurate reconstruction capabilities for 3D hidden objects. These results provide a 3D visualization with submillimeter accuracy for NLOS detection in challenging environmental conditions.

Förderung

  • National Natural Science Foundation of China
  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Liang, H., Wei, L., Qin, T., Bai, L., Shi, Y., Guo, E., & Han, J. (2026). Submillimeter non-line-of-sight ranging and imaging via cost-effective FMCW interferometry. Photonics Research, 14(7), 3005. https://doi.org/10.1364/prj.595776

Vancouver

Liang H, Wei L, Qin T, Bai L, Shi Y, Guo E, et al. Submillimeter non-line-of-sight ranging and imaging via cost-effective FMCW interferometry. Photonics Research. 2026;14(7):3005. doi:10.1364/prj.595776

BibTeX
@article{Liang2026,
  author = {Liang, Huan and Wei, Lingchuan and Qin, Taotao and Bai, Lianfa and Shi, Yingjie and Guo, Enlai and Han, Jing},
  title = {Submillimeter non-line-of-sight ranging and imaging via cost-effective FMCW interferometry},
  journal = {Photonics Research},
  year = {2026},
  volume = {14},
  number = {7},
  pages = {3005},
  doi = {10.1364/prj.595776}
}
Kostenlos starten →