Broadband dual-comb spectroscopy with efficient baseline normalization enabled by frequency-domain multiplexing
Photonics Research · 01.06.2026 · 14 (6) · 2490
DOI: 10.1364/prj.585494 ↗Kurz gefasst
Fachartikel in der Zeitschrift Photonics Research, online erschienen am 19.05.2026. Verfasst von Yukun Liao und 5 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Gefördert von: Jilin Provincial Natural Science Foundation, National Natural Science Foundation of China.
Abstract (Originalsprache)
Accurate baseline normalization is critical for reliable spectral retrieval in dual-comb spectroscopic gas sensing. To overcome the current limitations, such as poor real-time performance, computational complexity, user dependence, and reliance on prior absorption models, we propose a frequency-domain multiplexing approach. An acousto-optic modulator, inserted in the reference arm, introduces an overall frequency shift to the comb signal, leading to an adjustable separation of reference and sample signals. A transfer function then achieves efficient correlation and correction between the reference and sample signals. It enables rapid and robust normalization without time-domain apodization or reference spectrum reconstruction. Implemented in a mode-locked dual-comb spectrometer, this approach demonstrates robustness against source intensity fluctuations. Comparison with external-cavity diode laser scanning confirms the baseline normalization accuracy, with a maximum deviation of 2.9% and standard deviation of 0.35%. It enables us to retrieve the broad (∼10 THz ) absorption spectrum of mixing C 2 H 2 and CO 2 in a straightforward manner. With high robustness, low computational complexity, and minimal user dependence, it offers promising potential for high-precision, real-time dual-comb spectroscopic applications.
Förderung
- Jilin Provincial Natural Science Foundation
- National Natural Science Foundation of China
Zitieren
APA
Liao, Y., Hu, M., Zhang, H., Zhao, Y., Lv, J., & Wang, Q. (2026). Broadband dual-comb spectroscopy with efficient baseline normalization enabled by frequency-domain multiplexing. Photonics Research, 14(6), 2490. https://doi.org/10.1364/prj.585494
Vancouver
Liao Y, Hu M, Zhang H, Zhao Y, Lv J, Wang Q. Broadband dual-comb spectroscopy with efficient baseline normalization enabled by frequency-domain multiplexing. Photonics Research. 2026;14(6):2490. doi:10.1364/prj.585494
BibTeX
@article{Liao2026,
author = {Liao, Yukun and Hu, Mengpeng and Zhang, Hui and Zhao, Yingze and Lv, Jinguang and Wang, Qiang},
title = {Broadband dual-comb spectroscopy with efficient baseline normalization enabled by frequency-domain multiplexing},
journal = {Photonics Research},
year = {2026},
volume = {14},
number = {6},
pages = {2490},
doi = {10.1364/prj.585494}
}