EUVIMEDEUVIMED entdecken
Crossref

Low-cost prototype for real-time analysis using liquid crystal optical sensors in water quality assessment

M. Simone Soares, Francisco Gameiro, Jan Nedoma, Nuno Santos, Pedro L. Almeida, Carlos Marques

Photonics Research · 01.02.2025 · 13 (2) · 541

DOI: 10.1364/prj.543957 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Photonics Research, online erschienen am 31.01.2025. Verfasst von M. Simone Soares und 5 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 17 Literaturangaben. Gefördert von: European Commission, Fundação para a Ciência e a Tecnologia, VSB-Technical University of Ostrava.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the food production sector, quickly identifying potential hazards is crucial due to the resilience of many pathogens, which could lead to wasted production results and, more severely, epidemic outbreaks. E. coli monitoring is essential; however, traditional quality control methods in fish farming are often slow and intrusive, thus promoting an increase in fish stress and mortality rates. This paper presents an alternative method by utilizing a prototype inspired by polarized optical microscopy (POM), constructed with a Raspberry Pi microprocessor to assess pixel patterns and calculate analyte levels. The sensors are based on the immune complexation reactions between E. coli specific antibodies and the disruption of liquid crystal (LC) alignment, which are measured with the POM technique. The prototype yielded a sensitivity of 1.01 % ±0.17 % / log 10 (CFU/mL) for E. coli . In this paper, tests using sunlight as the prototype’s light source were also performed, and a user-friendly graphical user interface was designed.

Förderung

  • European Commission
  • Fundação para a Ciência e a Tecnologia
  • VSB-Technical University of Ostrava
  • FCT/MCTES

Zitieren

APA

Soares, M. S., Gameiro, F., Nedoma, J., Santos, N., Almeida, P. L., & Marques, C. (2025). Low-cost prototype for real-time analysis using liquid crystal optical sensors in water quality assessment. Photonics Research, 13(2), 541. https://doi.org/10.1364/prj.543957

Vancouver

Soares MS, Gameiro F, Nedoma J, Santos N, Almeida PL, Marques C. Low-cost prototype for real-time analysis using liquid crystal optical sensors in water quality assessment. Photonics Research. 2025;13(2):541. doi:10.1364/prj.543957

BibTeX
@article{Soares2025,
  author = {Soares, M. Simone and Gameiro, Francisco and Nedoma, Jan and Santos, Nuno and Almeida, Pedro L. and Marques, Carlos},
  title = {Low-cost prototype for real-time analysis using liquid crystal optical sensors in water quality assessment},
  journal = {Photonics Research},
  year = {2025},
  volume = {13},
  number = {2},
  pages = {541},
  doi = {10.1364/prj.543957}
}
Kostenlos starten →