EUVIMEDEUVIMED entdecken
Crossref

Structure decomposition for quantitative microarchitecture analysis via X-ray grating interferometry

Longchao Men, Peiyuan Guo, Jincheng Lu, Yongle Yan, Hongxia Yin, Yan Xu, Zhenchang Wang, Li Zhang, Zhentian Wang

Optica · 20.06.2026 · 13 (6) · 1104

DOI: 10.1364/optica.570829 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optica, online erschienen am 05.06.2026. Verfasst von Longchao Men und 8 weiteren Autor:innen. Die Arbeit nennt 62 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Beijing Natural Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitative assessment of unresolved microstructural alterations remains a challenge for conventional X-ray imaging, limited by spatial resolution and dose constraints. While X-ray dark-field imaging with grating interferometry provides high sensitivity to sub-resolution microstructures and has demonstrated considerable promise in the diagnosis of pulmonary diseases, the absence of a rigorously established signal-to-structure relationship has restricted its clinical studies to semi-quantitative analysis. Here, using a naturally close-packed microsphere model, whose dark-field signal characteristics closely resemble those of pulmonary tissue, we establish a deterministic relationship between microsphere diameter and linear diffusion coefficient in the regime where the microsphere diameter substantially exceeds the auto-correlation length—a condition commonly encountered in clinical dark-field imaging systems. This enables resolving unknown microsphere sizes through linear superposition of two basis microspheres. Our investigation also reveals the inherent limitation of dual-energy techniques in achieving such structure decomposition, stemming from unavoidable linearly energy-dependent behavior of the material’s linear diffusion coefficient. To address this, we present a quantitative framework featuring a single-energy (i.e., single energy spectrum) structure decomposition method. Experimental validation using 200 and 400µm diameter reference microspheres achieved precise diameter prediction (relative error of mean value

Förderung

  • National Natural Science Foundation of China
  • Beijing Natural Science Foundation

Zitieren

APA

Men, L., Guo, P., Lu, J., Yan, Y., Yin, H., Xu, Y., Wang, Z., Zhang, L., & Wang, Z. (2026). Structure decomposition for quantitative microarchitecture analysis via X-ray grating interferometry. Optica, 13(6), 1104. https://doi.org/10.1364/optica.570829

Vancouver

Men L, Guo P, Lu J, Yan Y, Yin H, Xu Y, et al. Structure decomposition for quantitative microarchitecture analysis via X-ray grating interferometry. Optica. 2026;13(6):1104. doi:10.1364/optica.570829

BibTeX
@article{Men2026,
  author = {Men, Longchao and Guo, Peiyuan and Lu, Jincheng and Yan, Yongle and Yin, Hongxia and Xu, Yan and Wang, Zhenchang and Zhang, Li and Wang, Zhentian},
  title = {Structure decomposition for quantitative microarchitecture analysis via X-ray grating interferometry},
  journal = {Optica},
  year = {2026},
  volume = {13},
  number = {6},
  pages = {1104},
  doi = {10.1364/optica.570829}
}
Kostenlos starten →