Multi-energy thickness–mobility optimization of MAPbI 3 and MAPbBr 3 perovskite direct-conversion X-ray detectors for tissue-specific medical imaging

Asik Nowaz Pieal, Nadia Rahman, Md. Junayed Bin Abdul Khalek, Naznin Sultana, Safayat-Al Imam

Optics Continuum · 15.11.2026 · 5 (11) · 3717

DOI: 10.1364/optcon.616657 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Continuum, online erschienen am 12.11.2026. Verfasst von Asik Nowaz Pieal und 4 weiteren Autor:innen. Die Arbeit nennt 60 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Perovskite direct-conversion X-ray detectors are strong candidates for medical imaging, but their performance couples photon energy, active-layer thickness, carrier transport, and applied field. We present an analytical multi-energy thickness–mobility optimization of MAPbI 3 and MAPbBr 3 detectors at 10, 20, 30, and 60 keV, combining NIST-derived attenuation coefficients with a charge-collection-efficiency (CCE) model and the exposure-referenced sensitivity formulation, verified by reproducing published simulated sensitivity curves at an X-ray energy of 20 keV. Lower photon energies require thinner layers, whereas the per-exposure maximum sensitivity rises monotonically across the four energies studied as the fluence per Roentgen increases. MAPbBr 3 attains higher CCE, larger optimum thickness, and greater sensitivity than MAPbI 3 . Raising MAPbI 3 mobilities toward single-crystal values increases the 60 keV sensitivity 4.25 × and lifts the optimum CCE from 39% to 89%. A three-dimensional thickness–mobility map locates a global optimum of 45.1 μ C·cm −2 ·R −1 at thickness L ≈ 892 μ m and quantifies a structural sensitivity–collection trade-off, yielding thickness guidelines for mammography, dental/bone, and chest imaging.

Zitieren

APA

Pieal, A. N., Rahman, N., Khalek, M. J. B. A., Sultana, N., & Imam, S. (2026). Multi-energy thickness–mobility optimization of MAPbI 3 and MAPbBr 3 perovskite direct-conversion X-ray detectors for tissue-specific medical imaging. Optics Continuum, 5(11), 3717. https://doi.org/10.1364/optcon.616657

Vancouver

Pieal AN, Rahman N, Khalek MJBA, Sultana N, Imam S. Multi-energy thickness–mobility optimization of MAPbI 3 and MAPbBr 3 perovskite direct-conversion X-ray detectors for tissue-specific medical imaging. Optics Continuum. 2026;5(11):3717. doi:10.1364/optcon.616657

BibTeX
@article{Pieal2026,
  author = {Pieal, Asik Nowaz and Rahman, Nadia and Khalek, Md. Junayed Bin Abdul and Sultana, Naznin and Imam, Safayat-Al},
  title = {Multi-energy thickness–mobility optimization of MAPbI 3 and MAPbBr 3 perovskite direct-conversion X-ray detectors for tissue-specific medical imaging},
  journal = {Optics Continuum},
  year = {2026},
  volume = {5},
  number = {11},
  pages = {3717},
  doi = {10.1364/optcon.616657}
}
Kostenlos starten →