Size estimation of mixed free-floating sub-resolution spherical scatterers utilizing adaptive scanning optical coherence tomography
Optics Continuum · 15.07.2026 · 5 (7) · 2096
DOI: 10.1364/optcon.597161 ↗Kurz gefasst
Fachartikel in der Zeitschrift Optics Continuum, online erschienen am 24.06.2026. Verfasst von Yuan Tian und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Duke University Medical Center, Durham, North Carolina 27710, USA. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NEI NIH HHS, United States Department of Defense, National Institutes of Health.
Abstract (Originalsprache)
Optical coherence tomography (OCT) is a volumetric imaging technique that enables real-time assessment of biological tissues with micrometer-scale resolution. This enables OCT to also offer the potential to estimate scatterer size. However, in cases where the axial and lateral resolution of the OCT system are larger than the target scatterer, it is difficult to assess the scatterer size directly within the OCT space domain. This paper presents a workflow to estimate diameters of individual free-floating spherical particles within OCT volumes, leveraging adaptive scanning, spectroscopic OCT, and Mie theory. Using this workflow, we demonstrate the capability to estimate individual microbead diameters ranging from 6 to 10 µm, both in isolation and within mixed solutions with 12 × speed up than the previous method. The results indicate that the proposed Mie backscattering approach yields size estimations that were statistically equivalent to labeled values. In experiments with a mixed solution containing microbeads of 6 µm, 8 µm, and 10 µm diameters, our method successfully differentiated the three bead sizes through histogram analysis.
Autor:innen und Institutionen
- Department of Ophthalmology, Duke University Medical Center, Durham, North Carolina 27710, USA.
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA.
ORCID-Profile: Yuan Tian, Ryan P Mcnabb
Förderung
- NEI NIH HHS
- United States Department of Defense
- National Institutes of Health
- Research to Prevent Blindness
Zitieren
APA
Tian, Y., Izatt, J. A., Kuo, A., & Mcnabb, R. P. (2026). Size estimation of mixed free-floating sub-resolution spherical scatterers utilizing adaptive scanning optical coherence tomography. Optics Continuum, 5(7), 2096. https://doi.org/10.1364/optcon.597161
Vancouver
Tian Y, Izatt JA, Kuo A, Mcnabb RP. Size estimation of mixed free-floating sub-resolution spherical scatterers utilizing adaptive scanning optical coherence tomography. Optics Continuum. 2026;5(7):2096. doi:10.1364/optcon.597161
BibTeX
@article{Tian2026,
author = {Tian, Yuan and Izatt, Joseph A and Kuo, Anthony and Mcnabb, Ryan P},
title = {Size estimation of mixed free-floating sub-resolution spherical scatterers utilizing adaptive scanning optical coherence tomography},
journal = {Optics Continuum},
year = {2026},
volume = {5},
number = {7},
pages = {2096},
doi = {10.1364/optcon.597161}
}
EUVIMED