EUVIMEDEUVIMED entdecken
Crossref

Performance evaluation of CsPbX 3 (X=Br, I) perovskites for X-ray detection in mammography and chest radiography

Naznin Sultana, Ahmed Zubair

Optics Continuum · 15.04.2025 · 4 (4) · 895

DOI: 10.1364/optcon.550029 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Continuum, online erschienen am 15.04.2025. Verfasst von Naznin Sultana und 1 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper investigates the performance of the inorganic perovskite CsPbX 3 (X=Br, I) direct X-ray detectors in medical diagnostics, i.e., mammography (20 keV) and chest radiography (60 keV) using the analytical model of photocurrent and sensitivity. Appropriate optical and electrical properties reported in previous works are employed to determine the sensitivity to 20 and 60 keV monoenergetic X-rays for the CsPbX 3 detector. The optimum thickness for CsPbI 3 and CsPbBr 3 is found to be ∼250-400 µ m and ∼150-280 µ m, respectively, for mammography for various electric fields. It has been determined that, for chest radiography under various applied electric fields, the ideal thicknesses for both CsPbI 3 and CsPbBr 3 are ∼1-2.5 mm. A low electric field (≤ 0.1 V/ µ m) is sufficient to obtain maximum sensitivity for the CsPbX 3 detector. The sensitivity obtained for mammography for CsPbI 3 and CsPbBr 3 is 316 and 216 µ CGy −1 cm −2 , respectively, at 0.1 V/ µ m higher than commercially available a-Se X-ray photoconductor, whereas for chest radiology, CsPbI 3 and CsPbBr 3 show sensitivity of ∼4000 and ∼3000 µ CGy −1 cm −2 , respectively. The sensitivity of CsPbBX 3 is not appreciably impacted by electron or hole lifetimes longer than 10 µ s. According to the theoretical study, if thorough research is done to enhance the charge carrier transport properties and optimize the photoconductor design, the CsPbX 3 perovskite can be an excellent candidate in medical X-ray imaging.

Zitieren

APA

Sultana, N., & Zubair, A. (2025). Performance evaluation of CsPbX 3 (X=Br, I) perovskites for X-ray detection in mammography and chest radiography. Optics Continuum, 4(4), 895. https://doi.org/10.1364/optcon.550029

Vancouver

Sultana N, Zubair A. Performance evaluation of CsPbX 3 (X=Br, I) perovskites for X-ray detection in mammography and chest radiography. Optics Continuum. 2025;4(4):895. doi:10.1364/optcon.550029

BibTeX
@article{Sultana2025,
  author = {Sultana, Naznin and Zubair, Ahmed},
  title = {Performance evaluation of CsPbX 3 (X=Br, I) perovskites for X-ray detection in mammography and chest radiography},
  journal = {Optics Continuum},
  year = {2025},
  volume = {4},
  number = {4},
  pages = {895},
  doi = {10.1364/optcon.550029}
}
Kostenlos starten →