EUVIMEDEUVIMED entdecken
Crossref

Ultrasensitive refractive index sensing of optical microfiber couplers coated with Ti 3 C 2 MXene

Rui Peng, Wenchao Zhou, Yihui Wu, Zeyuan Song, Haiyang Yu

Optical Materials Express · 01.05.2024 · 14 (5) · 1268

DOI: 10.1364/ome.520614 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optical Materials Express, online erschienen am 11.04.2024. Verfasst von Rui Peng und 4 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Youth Innovation Promotion Association of the Chinese Academy of Sciences, National Natural Science Foundation of China, Industrialization Innovation Team Project of Foshan Institute of Industrial Technology, Chinese Academy of Sciences.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Two-dimensional (2D) MXene has recently been found to play a significant role in constructing biosensing platforms due to its excellent biocompatibility, large specific surface area, and broad optical absorption. In this article, an ultra-sensitive refractive index (RI) sensor based on an optical microfiber coupler (OMC) coated with Ti 3 C 2 MXene is proposed and experimentally demonstrated. Numerical results reveal that surface modification of MXene enhances the RI sensitivity of OMC and creates a new artificial dispersion turning point (ADTP). The OMC with a dispersion turning point (DTP) at 1300 nm is fabricated using a hybrid fusion elongation-wet etching method. It has a waist width of approximately 2.46 µm. We experimentally achieved the RI sensitivity of 9.1 × 10 4 ± 0.42 × 10 4 nm/RIU using the OMC. MXene improves the sensitivity of the OMC because Ti 3 C 2 MXene can change the effective refractive index (ERI) for both the even and odd modes, leading to the interference dips shifting closer to the DTP. The experimental results demonstrate that the RI sensitivity of the OMC coated with Ti 3 C 2 MXene can reach -1.7 × 10 5 ± 0.2 × 10 5 nm/RIU, which shows a ∼87% sensitivity boost compared with bare OMC. The proposed sensor is expected to be used for high-sensitivity biochemical molecule detection.

Förderung

  • Youth Innovation Promotion Association of the Chinese Academy of Sciences
  • National Natural Science Foundation of China
  • Industrialization Innovation Team Project of Foshan Institute of Industrial Technology, Chinese Academy of Sciences

Zitieren

APA

Peng, R., Zhou, W., Wu, Y., Song, Z., & Yu, H. (2024). Ultrasensitive refractive index sensing of optical microfiber couplers coated with Ti 3 C 2 MXene. Optical Materials Express, 14(5), 1268. https://doi.org/10.1364/ome.520614

Vancouver

Peng R, Zhou W, Wu Y, Song Z, Yu H. Ultrasensitive refractive index sensing of optical microfiber couplers coated with Ti 3 C 2 MXene. Optical Materials Express. 2024;14(5):1268. doi:10.1364/ome.520614

BibTeX
@article{Peng2024,
  author = {Peng, Rui and Zhou, Wenchao and Wu, Yihui and Song, Zeyuan and Yu, Haiyang},
  title = {Ultrasensitive refractive index sensing of optical microfiber couplers coated with Ti 3 C 2 MXene},
  journal = {Optical Materials Express},
  year = {2024},
  volume = {14},
  number = {5},
  pages = {1268},
  doi = {10.1364/ome.520614}
}
Kostenlos starten →