EUVIMEDEUVIMED entdecken
Leserbrief

Improving precision in ratiometric fluorescence thermometry through optical signal uncertainty optimization

Changwen Wang, Yahuan Zhang, Min Liang, Meng Kou, Yongda Wang, Zhiguo Zhang, Yunfei Chang

Optics Letters · 15.11.2026 · 51 (22) · 6267

DOI: 10.1364/ol.618903 ↗

Kurz gefasst

Leserbrief in der Zeitschrift Optics Letters, online erschienen am 06.11.2026. Verfasst von Changwen Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Zhengzhou Advanced Research Institute of Harbin Institute of Technology, Harbin Institute of Technology, Zhengzhou 450000, China. Die Arbeit nennt 25 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Heilongjiang Provincial Natural Science Foundation of China, State Key Laboratory of New Ceramic Materials Tsinghua University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Measurement precision is a key figure of merit in optical measurements. However, precision in ratiometric fluorescence thermometry is constrained by its underlying physical principles. We identify weak signals as a major source of temperature uncertainty and propose optical signal uncertainty optimization to improve thermometric precision. In a representative thermally coupled system, optimization increases the maximum relative sensitivity to 2.1 times its original value and reduces the minimum temperature uncertainty by approximately 45%, both at 563 K. This method offers a route to improved precision in ratiometric optical measurements with asymmetric signal uncertainties.

Autor:innen und Institutionen

  • Zhengzhou Advanced Research Institute of Harbin Institute of Technology, Harbin Institute of Technology, Zhengzhou 450000, China.
  • School of Instrumentation Science and Engineering, Harbin Institute of Technology, Harbin 150001, China.
  • Key Laboratory for Photonic and Electronic Bandgap Materials, Ministry of Education, School of Physics and Electronic Engineering, Harbin Normal University, Harbin 150025, China.
  • Research Center for Crystal Materials, State Key Laboratory of Functional Materials and Devices for Special Environmental Conditions, Xinjiang Key Laboratory of Functional Crystal Materials, Xinjiang Technical Institute…
  • Yongkang Hardware College, Zhejiang University of Technology, Jinhua, 321300, China.

Förderung

  • National Natural Science Foundation of China
  • Heilongjiang Provincial Natural Science Foundation of China
  • State Key Laboratory of New Ceramic Materials Tsinghua University

Zitieren

APA

Wang, C., Zhang, Y., Liang, M., Kou, M., Wang, Y., Zhang, Z., & Chang, Y. (2026). Improving precision in ratiometric fluorescence thermometry through optical signal uncertainty optimization. Optics Letters, 51(22), 6267. https://doi.org/10.1364/ol.618903

Vancouver

Wang C, Zhang Y, Liang M, Kou M, Wang Y, Zhang Z, et al. Improving precision in ratiometric fluorescence thermometry through optical signal uncertainty optimization. Optics Letters. 2026;51(22):6267. doi:10.1364/ol.618903

BibTeX
@article{Wang2026,
  author = {Wang, Changwen and Zhang, Yahuan and Liang, Min and Kou, Meng and Wang, Yongda and Zhang, Zhiguo and Chang, Yunfei},
  title = {Improving precision in ratiometric fluorescence thermometry through optical signal uncertainty optimization},
  journal = {Optics Letters},
  year = {2026},
  volume = {51},
  number = {22},
  pages = {6267},
  doi = {10.1364/ol.618903}
}
Kostenlos starten →