RF-referenced and phase-tracking-based precise measurement of optical resonator free spectral range across a broad wavelength range
Optics Letters · 01.11.2026 · 51 (21) · 6119
DOI: 10.1364/ol.616191 ↗Kurz gefasst
Leserbrief in der Zeitschrift Optics Letters, online erschienen am 30.10.2026. Verfasst von Yuqi Yu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Education Ministry for Modern Design and Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China. Die Arbeit nennt 29 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
The free spectral range (FSR) is a key parameter in the design of optical resonators. However, material dispersion can cause nonuniform FSR variations across a broad wavelength range. To address this drawback, this study proposes a high-precision FSR measurement method that combines an electro-optic modulator with an orthogonal Mach–Zehnder interferometer (MZI). A tunable laser is electro-optically modulated to generate equally spaced sidebands, yielding stable frequency markers. Subsequently, the markers are combined with the unwrapped instantaneous phases obtained from the MZI to determine high-precision FSR. Using a fiber ring resonator as a representative example, the FSR varied by ~51.4 kHz over an 82.4-nm wavelength span. The measured FSR was used as a frequency-interval reference, together with the known absolute wavelength of the R9 line, to determine the center wavelengths of H 13 C 14 N gas absorption lines. As a result, an absolute measurement accuracy better than 0.24 pm was achieved, demonstrating the method’s high precision and reliability. Thus, the proposed method enables high-precision characterization of optical resonator parameters across a wide spectral range and offers a practical approach to precision spectroscopy.
Autor:innen und Institutionen
- Key Laboratory of Education Ministry for Modern Design and Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China.
ORCID-Profile: Weijin Meng, Zhigang Liu
Förderung
- National Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities
Zitieren
APA
Yu, Y., Guo, J., Meng, W., Peng, H., Huang, Z., & Liu, Z. (2026). RF-referenced and phase-tracking-based precise measurement of optical resonator free spectral range across a broad wavelength range. Optics Letters, 51(21), 6119. https://doi.org/10.1364/ol.616191
Vancouver
Yu Y, Guo J, Meng W, Peng H, Huang Z, Liu Z. RF-referenced and phase-tracking-based precise measurement of optical resonator free spectral range across a broad wavelength range. Optics Letters. 2026;51(21):6119. doi:10.1364/ol.616191
BibTeX
@article{Yu2026,
author = {Yu, Yuqi and Guo, Junkang and Meng, Weijin and Peng, Hu and Huang, Zhenkun and Liu, Zhigang},
title = {RF-referenced and phase-tracking-based precise measurement of optical resonator free spectral range across a broad wavelength range},
journal = {Optics Letters},
year = {2026},
volume = {51},
number = {21},
pages = {6119},
doi = {10.1364/ol.616191}
}
EUVIMED