EUVIMEDEUVIMED entdecken
Leserbrief

Accuracy-enhanced ultra-wideband optoelectronic frequency response measurement via residual carrier de-embedding and sideband power correction

Yuqing Heng, Qi Wang, Jianbin Fu, Xingbang Zhu, Min Xue iD, Shilong Pan iD

Optics Letters · 15.11.2026 · 51 (22) · 6147

DOI: 10.1364/ol.613747 ↗

Kurz gefasst

Leserbrief in der Zeitschrift Optics Letters, online erschienen am 02.11.2026. Verfasst von Yuqing Heng und 5 weiteren Autor:innen. Beteiligte Einrichtung: National Key Laboratory of Microwave Photonics, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China. Die Arbeit nennt 19 Literaturangaben. Gefördert von: National Natural Science Foundation of China, HK RGC GRF, Project of Key Laboratory of Radar Imaging and Microwave Photonics (Nanjing University of Aeronautics and Astronautics), Ministry of Education.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We propose and experimentally demonstrate an accuracy-enhanced optoelectronic ultra-wideband frequency response measurement method for photodetector (PD) characterization utilizing residual carrier de-embedding and sideband power correction. The optical probe signal that is injected into the PD under test is a carrier-suppressed optical double-sideband (ODSB) signal produced by a Mach–Zehnder modulator (MZM) operating at the minimum transmission point (MITP). By simultaneously monitoring the optical spectrum and total power of the probe signal, the individual powers of the two first-order sidebands can be accurately derived, thereby eliminating errors caused by residual carrier and sideband power imbalance. Combined with the measurement of the second-harmonic component in the generated photocurrent, this correction enables accurate frequency response measurement over an ultra-wideband. The proposed method is inherently robust against finite MZM extinction ratio and high-frequency modulation degradation, while doubling the measurable bandwidth. Experimentally, a commercial ultra-wideband PD is characterized from 20 MHz to 110 GHz using an MZM with a 6-dB bandwidth exceeding 60 GHz. The results confirm a substantial improvement in measurement accuracy compared with the conventional method.

Autor:innen und Institutionen

  • National Key Laboratory of Microwave Photonics, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China.
  • Newkey Photonics Information Technology Limited Liability Company, Nanjing 210016, China.

ORCID-Profile: Min Xue, Shilong Pan

Förderung

  • National Natural Science Foundation of China
  • HK RGC GRF
  • Project of Key Laboratory of Radar Imaging and Microwave Photonics (Nanjing University of Aeronautics and Astronautics), Ministry of Education

Zitieren

APA

Heng, Y., Wang, Q., Fu, J., Zhu, X., Xue, M., & Pan, S. (2026). Accuracy-enhanced ultra-wideband optoelectronic frequency response measurement via residual carrier de-embedding and sideband power correction. Optics Letters, 51(22), 6147. https://doi.org/10.1364/ol.613747

Vancouver

Heng Y, Wang Q, Fu J, Zhu X, Xue M, Pan S. Accuracy-enhanced ultra-wideband optoelectronic frequency response measurement via residual carrier de-embedding and sideband power correction. Optics Letters. 2026;51(22):6147. doi:10.1364/ol.613747

BibTeX
@article{Heng2026,
  author = {Heng, Yuqing and Wang, Qi and Fu, Jianbin and Zhu, Xingbang and Xue, Min and Pan, Shilong},
  title = {Accuracy-enhanced ultra-wideband optoelectronic frequency response measurement via residual carrier de-embedding and sideband power correction},
  journal = {Optics Letters},
  year = {2026},
  volume = {51},
  number = {22},
  pages = {6147},
  doi = {10.1364/ol.613747}
}
Kostenlos starten →