EUVIMEDEUVIMED entdecken
Crossref

Sensitive detection of Si 3 N 4 thin-film defects via second harmonic generation microscopy

J Lukeš, V Hájková, M Hlubučková, V Kanclíř, K Žídek

Optics Letters · 15.03.2025 · 50 (6) · 1885

DOI: 10.1364/ol.553380 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Letters, online erschienen am 06.03.2025. Verfasst von J Lukeš und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Ministerstvo Školství, Mládeže a Tělovýchovy, Technická Univerzita v Liberci.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optical coating, an integral part of many optical systems, is prone to damage from environmental exposure and laser irradiation. This underscores the need for reliable and sensitive coating diagnostics. We introduce second harmonic generation (SHG) as a method for the sensitive detection of defects and inhomogeneities within optical thin films. We demonstrate the use of SHG on Si 3 N 4 layers tested for their laser-induced damage threshold. The SHG mapping was compared with commonly used diagnostic techniques, including Nomarski microscopy, white light interferometry, and electron microscopy. Owing to its sensitivity to variations in local symmetry, SHG is able to discern minute alterations in material composition, mechanical stress, and interface structures. Therefore, SHG identified modifications in the tested layers, highly extending the damage recognized by standard methods. Furthermore, we demonstrate SHG's ability to enhance specific features by modulation of incidence angles and polarization modes. Based on these findings, we propose SHG as an ideal diagnostic tool for the early identification of laser-induced modifications in centrosymmetric thin films.

Förderung

  • Ministerstvo Školství, Mládeže a Tělovýchovy
  • Technická Univerzita v Liberci

Zitieren

APA

Lukeš, J., Hájková, V., Hlubučková, M., Kanclíř, V., & Žídek, K. (2025). Sensitive detection of Si 3 N 4 thin-film defects via second harmonic generation microscopy. Optics Letters, 50(6), 1885. https://doi.org/10.1364/ol.553380

Vancouver

Lukeš J, Hájková V, Hlubučková M, Kanclíř V, Žídek K. Sensitive detection of Si 3 N 4 thin-film defects via second harmonic generation microscopy. Optics Letters. 2025;50(6):1885. doi:10.1364/ol.553380

BibTeX
@article{Luke2025,
  author = {Lukeš, J and Hájková, V and Hlubučková, M and Kanclíř, V and Žídek, K},
  title = {Sensitive detection of Si 3 N 4 thin-film defects via second harmonic generation microscopy},
  journal = {Optics Letters},
  year = {2025},
  volume = {50},
  number = {6},
  pages = {1885},
  doi = {10.1364/ol.553380}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.