EUVIMEDEUVIMED entdecken
Crossref

Phase-coded coherent microwave pulse generation based on an actively mode-locked optoelectronic parametric oscillator

Hang Xiao, Di Peng, Ya Han, Quandong Huang, Shuoyang Qiu, Jianping Li, Meng Xiang, Songnian Fu, Yuwen Qin

Optics Letters · 15.12.2024 · 49 (24) · 6956

DOI: 10.1364/ol.544315 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Letters, online erschienen am 03.12.2024. Verfasst von Hang Xiao und 8 weiteren Autor:innen. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 17 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Open Fund of the Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Guangdong Introducing Innovative and Entrepreneurial Teams of “The Pearl River Talent Recruitment Program”.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An approach for generating phase-coded coherent microwave pulse trains at high frequencies is proposed and demonstrated based on an actively mode-locked optoelectronic parametric oscillator (AML-OEPO), where an electrical mixer is inserted into the cavity of an optoelectronic oscillator (OEO) to achieve both mode locking and parameter oscillation. The driving signal applied to the mixer is a low-frequency sinusoidal signal with voltage polarity coding, where the frequency is the same as the free spectral range (FSR) of the OEO cavity, and the duration of each voltage polarity coding bit is identical to the loop delay. As a result, phase-coded coherent microwave pulse trains can be generated, where the pulse interval is equal to the loop delay due to the active mode locking effect, and the phase coding period is equal to a multiple integer of the loop delay due to parameter oscillation. The enhancement of the signal period and the highly coherent characteristic are beneficial for breaking the contradiction between unambiguous detection range and ranging resolution in pulse radars. In the experiment, phase-coded microwave pulse trains with either 13-bit barker codes or 7-bit M codes are generated at 15.026 GHz. The autocorrelation calculation result of the phase-coded microwave pulse train with 13-bit barker codes shows a high peak-to-sidelobe ratio, verifying high coherence.

Förderung

  • National Natural Science Foundation of China
  • Open Fund of the Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications
  • Guangdong Introducing Innovative and Entrepreneurial Teams of “The Pearl River Talent Recruitment Program”

Zitieren

APA

Xiao, H., Peng, D., Han, Y., Huang, Q., Qiu, S., Li, J., Xiang, M., Fu, S., & Qin, Y. (2024). Phase-coded coherent microwave pulse generation based on an actively mode-locked optoelectronic parametric oscillator. Optics Letters, 49(24), 6956. https://doi.org/10.1364/ol.544315

Vancouver

Xiao H, Peng D, Han Y, Huang Q, Qiu S, Li J, et al. Phase-coded coherent microwave pulse generation based on an actively mode-locked optoelectronic parametric oscillator. Optics Letters. 2024;49(24):6956. doi:10.1364/ol.544315

BibTeX
@article{Xiao2024,
  author = {Xiao, Hang and Peng, Di and Han, Ya and Huang, Quandong and Qiu, Shuoyang and Li, Jianping and Xiang, Meng and Fu, Songnian and Qin, Yuwen},
  title = {Phase-coded coherent microwave pulse generation based on an actively mode-locked optoelectronic parametric oscillator},
  journal = {Optics Letters},
  year = {2024},
  volume = {49},
  number = {24},
  pages = {6956},
  doi = {10.1364/ol.544315}
}
Kostenlos starten →