EUVIMEDEUVIMED entdecken
Crossref

Fiber-coupled 2 mL vacuum-gap Fabry–Perot reference cavity for portable laser stabilization

Charles A McLemore, Naijun Jin, Megan L Kelleher, Yizhi Luo, Dahyeon Lee, Yifan Liu, Takuma Nakamura, David Mason, Peter Rakich, Scott A Diddams, Franklyn Quinlan

Optics Letters · 15.08.2024 · 49 (16) · 4737

DOI: 10.1364/ol.531169 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Letters, online erschienen am 15.08.2024. Verfasst von Charles A McLemore und 10 weiteren Autor:innen. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: Defense Advanced Research Projects Agency, National Institute of Standards and Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Vacuum-gap Fabry–Perot cavities are indispensable for the realization of frequency-stable lasers, with applications across a diverse range of scientific and industrial pursuits. However, making these cavity-based laser stabilization systems compact, portable, and rugged enough for use outside of controlled laboratory conditions has proven difficult. Here, we present a fiber-coupled 1396 nm laser stabilization system requiring no free-space optics or alignment, built for a portable strontium optical lattice clock. Based on a 2 mL vacuum-gap Fabry–Perot cavity, this system demonstrates thermal noise-limited performance and 1 × 10 −14 fractional frequency instability. Fiber-integrated optical components have been instrumental in both advancing the field of optics and leveraging those advances across disciplines to facilitate other fields of study. This portable system represents a major step toward making the frequency stability of cavity-based systems broadly accessible.

Förderung

  • Defense Advanced Research Projects Agency
  • National Institute of Standards and Technology

Zitieren

APA

McLemore, C. A., Jin, N., Kelleher, M. L., Luo, Y., Lee, D., Liu, Y., Nakamura, T., Mason, D., Rakich, P., Diddams, S. A., & Quinlan, F. (2024). Fiber-coupled 2 mL vacuum-gap Fabry–Perot reference cavity for portable laser stabilization. Optics Letters, 49(16), 4737. https://doi.org/10.1364/ol.531169

Vancouver

McLemore CA, Jin N, Kelleher ML, Luo Y, Lee D, Liu Y, et al. Fiber-coupled 2 mL vacuum-gap Fabry–Perot reference cavity for portable laser stabilization. Optics Letters. 2024;49(16):4737. doi:10.1364/ol.531169

BibTeX
@article{McLemore2024,
  author = {McLemore, Charles A and Jin, Naijun and Kelleher, Megan L and Luo, Yizhi and Lee, Dahyeon and Liu, Yifan and Nakamura, Takuma and Mason, David and Rakich, Peter and Diddams, Scott A and Quinlan, Franklyn},
  title = {Fiber-coupled 2 mL vacuum-gap Fabry–Perot reference cavity for portable laser stabilization},
  journal = {Optics Letters},
  year = {2024},
  volume = {49},
  number = {16},
  pages = {4737},
  doi = {10.1364/ol.531169}
}