Micrometer-precision absolute distance measurement with a repetition-rate-locked soliton microcomb
Optics Letters · 15.08.2023 · 48 (16) · 4356
DOI: 10.1364/ol.499291 ↗Kurz gefasst
Fachartikel in der Zeitschrift Optics Letters, online erschienen am 10.08.2023. Verfasst von Mingyue Yang und 8 weiteren Autor:innen. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Natural Science Foundation for Distinguished Young Scholars of Hunan Province, Natural Science Foundation of Hunan Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
The soliton microcomb has sparked interest in high-precision distance measurement, owing to its ultrahigh repetition rate and chip-integrated scale. We report absolute distance measurements based on synthetic wavelength interferometry with a soliton microcomb. We stabilized the repetition rate of 48.98 GHz through injection locking, with fluctuations below 0.25 Hz. Distance measurements up to 64 mm were demonstrated, presenting residuals below 2.7 μ m compared with a referenced laser interferometer. Long-term distance measurements were made at two fixed positions of approximately 0.2 m and 1.4 m, resulting in a minimum Allan deviation as low as 56.2 nm at an average time of 0.05 s. The dynamic demonstration illustrated that the proposed system could track round-trip motion of 3 mm at speeds up to 100 mm/s. The proposed distance measurement system is, to our knowledge, the first microcomb-based synthetic wavelength interferometer and achieves a ranging precision of tens of nanometers, with potential applications in the fields of satellite formation flying, high-end manufacturing, and micro–nano processing.
Förderung
- Natural Science Foundation for Distinguished Young Scholars of Hunan Province
- Natural Science Foundation of Hunan Province
- National Natural Science Foundation of China
Zitieren
APA
Yang, M., Wang, G., Wang, Z., Li, X., Zhu, L., Wang, W., Zhang, W., Yan, S., & Yang, J. (2023). Micrometer-precision absolute distance measurement with a repetition-rate-locked soliton microcomb. Optics Letters, 48(16), 4356. https://doi.org/10.1364/ol.499291
Vancouver
Yang M, Wang G, Wang Z, Li X, Zhu L, Wang W, et al. Micrometer-precision absolute distance measurement with a repetition-rate-locked soliton microcomb. Optics Letters. 2023;48(16):4356. doi:10.1364/ol.499291
BibTeX
@article{Yang2023,
author = {Yang, Mingyue and Wang, Guochao and Wang, Zhichuang and Li, Xianbin and Zhu, Lingxiao and Wang, Weiqiang and Zhang, Wenfu and Yan, Shuhua and Yang, Jun},
title = {Micrometer-precision absolute distance measurement with a repetition-rate-locked soliton microcomb},
journal = {Optics Letters},
year = {2023},
volume = {48},
number = {16},
pages = {4356},
doi = {10.1364/ol.499291}
}
EUVIMED