EUVIMEDEUVIMED entdecken
Crossref

Joint calibration of multiple line-structured light sensors and a common rotation axis using two unregistered 3D targets

Jindong Li, Shuofei Liang, Guiyuan Gao, Teng Qiu, Pengfei Zhang, Beibei Jin, Xiaohui Song

Optics Express · 30.11.2026 · 34 (24) · 45453

DOI: 10.1364/oe.619383 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 16.11.2026. Verfasst von Jindong Li und 6 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Joint Fund of Henan Province Science and Technology R&D Program, Key Research and Development Project of Henan Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Calibration of rotary scanning systems with multiple line-structured-light sensors is challenging when the sensors do not share a common field of view and a single calibration target cannot cover all measurement regions. This paper presents a joint calibration method using two independently placed 3D targets with known internal geometries but an unknown relative pose. Their common rotational motion supplies a motion-induced cross-target constraint that enables joint estimation of the target poses, sensor extrinsics, and rotation-axis parameters without requiring coplanar laser planes or a large common target. A staged optimization strategy begins with using the point-to-plane model and compact observation subsets to obtain reliable initial estimates, followed by joint refinement using a covariance-weighted line-parameter model and the complete dataset. Experiments on a three-sensor system yield a point-to-plane RMSE of 0.020 mm and a maximum absolute dimensional error of 0.025 mm over the evaluated gauge-block dimensions. The results demonstrate that the proposed method achieves accuracy comparable to single-large-target calibration while providing greater flexibility in target placement.

Förderung

  • National Natural Science Foundation of China
  • Joint Fund of Henan Province Science and Technology R&D Program
  • Key Research and Development Project of Henan Province
  • Fundamental Research Fund of Henan Academy of Sciences
  • Scientific and Technological Research Project of Henan Academy of Sciences

Zitieren

APA

Li, J., Liang, S., Gao, G., Qiu, T., Zhang, P., Jin, B., & Song, X. (2026). Joint calibration of multiple line-structured light sensors and a common rotation axis using two unregistered 3D targets. Optics Express, 34(24), 45453. https://doi.org/10.1364/oe.619383

Vancouver

Li J, Liang S, Gao G, Qiu T, Zhang P, Jin B, et al. Joint calibration of multiple line-structured light sensors and a common rotation axis using two unregistered 3D targets. Optics Express. 2026;34(24):45453. doi:10.1364/oe.619383

BibTeX
@article{Li2026,
  author = {Li, Jindong and Liang, Shuofei and Gao, Guiyuan and Qiu, Teng and Zhang, Pengfei and Jin, Beibei and Song, Xiaohui},
  title = {Joint calibration of multiple line-structured light sensors and a common rotation axis using two unregistered 3D targets},
  journal = {Optics Express},
  year = {2026},
  volume = {34},
  number = {24},
  pages = {45453},
  doi = {10.1364/oe.619383}
}
Kostenlos starten →