EUVIMEDEUVIMED entdecken
Crossref

Realization of a primary irradiance scale for solar irradiance measurements based on a predictable quantum efficient detector and a quasi-monochromatic portable tunable source

Geiland Porrovecchio, Julian Gröbner, Marek Smid

Optics Express · 16.11.2026 · 34 (23) · 43090

DOI: 10.1364/oe.607165 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 02.11.2026. Verfasst von Geiland Porrovecchio und 2 weiteren Autor:innen. Die Arbeit nennt 10 Literaturangaben. Gefördert von: European Partnership on Metrology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Long-term solar ultraviolet (UV) monitoring for climate modeling and ozone trend assessment demands exceptionally low measurement uncertainties. Traditional lamp-based radiometric calibrations using standard FEL lamps suffer from high intrinsic uncertainties in the UV region and are highly susceptible to drift over time. To address this gap, this work presents a primary, detector-based irradiance scale for solar UV measurements covering the 350 nm to 550 nm spectral range of the QASUME reference solar spectroradiometer. The proposed scale relies on a predictable quantum efficient detector (PQED) built with self-induced silicon photodiodes in a trap configuration. While PQEDs naturally exhibit near-unitary internal quantum efficiency between 450 nm and 850 nm, their extension into the UV requires accounting for impact ionization via an enhanced Quantum Yield effect. By implementing a validated quantum Yield model experimentally verified against the cryogenic radiometer primary standard at the Czech Metrology Institute (CMI), the scale achieves an estimated primary irradiance standard uncertainty of 0.28% in the near-UV range (350–425 nm) and 0.20% at wavelengths longer than 425 nm, which is a factor of 2 improvement compared to the current source-based scale. The realization of the detector-based scale is based on a transportable tunable light source (TuPS) alongside an automated comparison facility comprising a PQED as the primary irradiance reference, establishing an in-situ, highly accurate traceability chain for the QASUME reference spectroradiometer.

Förderung

  • European Partnership on Metrology

Zitieren

APA

Porrovecchio, G., Gröbner, J., & Smid, M. (2026). Realization of a primary irradiance scale for solar irradiance measurements based on a predictable quantum efficient detector and a quasi-monochromatic portable tunable source. Optics Express, 34(23), 43090. https://doi.org/10.1364/oe.607165

Vancouver

Porrovecchio G, Gröbner J, Smid M. Realization of a primary irradiance scale for solar irradiance measurements based on a predictable quantum efficient detector and a quasi-monochromatic portable tunable source. Optics Express. 2026;34(23):43090. doi:10.1364/oe.607165

BibTeX
@article{Porrovecchio2026,
  author = {Porrovecchio, Geiland and Gröbner, Julian and Smid, Marek},
  title = {Realization of a primary irradiance scale for solar irradiance measurements based on a predictable quantum efficient detector and a quasi-monochromatic portable tunable source},
  journal = {Optics Express},
  year = {2026},
  volume = {34},
  number = {23},
  pages = {43090},
  doi = {10.1364/oe.607165}
}
Kostenlos starten →