EUVIMEDEUVIMED entdecken
Crossref

In-situ measurement of vapor cell temperature based on obliquely incident pump light for NMR sensors

Chuanming Yin, Xiangyang Zhou, Weiqian Wang, Zhen Li, Bowen Liu, Zihao Lyu, Jinguo Mu, Zehao Wang, Xiaoxuan Xie

Optics Express · 15.06.2026 · 34 (12) · 23086

DOI: 10.1364/oe.604431 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 12.06.2026. Verfasst von Chuanming Yin und 8 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation, Innovation Program for Quantum Science and Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents a pump-light-based in-situ temperature measurement method for nuclear magnetic resonance (NMR) vapor cells under oblique optical incidence. To miniaturize the NMR sensor, a thin vapor cell is employed, in which both the orthogonal pump and probe light are introduced obliquely through one surface of the vapor cell. A model is developed to relate pump-light absorption to Rb atomic density, thereby enabling inference of the vapor cell temperature. The model includes polarization distortion, polarization-dependent window transmission attenuation, effective optical path length, and the coupling between optical absorption and atomic polarization. Experimental results show that the proposed method achieves the lowest RMSE of 0.179 K and reduces it by at least 68.2% compared with several commonly used fitting methods, enabling accurate in-situ temperature measurement in miniaturized NMR sensors under obliquely incident pumping.

Förderung

  • National Natural Science Foundation of China
  • China Postdoctoral Science Foundation
  • Innovation Program for Quantum Science and Technology

Zitieren

APA

Yin, C., Zhou, X., Wang, W., Li, Z., Liu, B., Lyu, Z., Mu, J., Wang, Z., & Xie, X. (2026). In-situ measurement of vapor cell temperature based on obliquely incident pump light for NMR sensors. Optics Express, 34(12), 23086. https://doi.org/10.1364/oe.604431

Vancouver

Yin C, Zhou X, Wang W, Li Z, Liu B, Lyu Z, et al. In-situ measurement of vapor cell temperature based on obliquely incident pump light for NMR sensors. Optics Express. 2026;34(12):23086. doi:10.1364/oe.604431

BibTeX
@article{Yin2026,
  author = {Yin, Chuanming and Zhou, Xiangyang and Wang, Weiqian and Li, Zhen and Liu, Bowen and Lyu, Zihao and Mu, Jinguo and Wang, Zehao and Xie, Xiaoxuan},
  title = {In-situ measurement of vapor cell temperature based on obliquely incident pump light for NMR sensors},
  journal = {Optics Express},
  year = {2026},
  volume = {34},
  number = {12},
  pages = {23086},
  doi = {10.1364/oe.604431}
}
Kostenlos starten →