EUVIMEDEUVIMED entdecken
Crossref

Line-scanning Brillouin microscopy with multiplexed two-stage VIPA spectrometer

Chenjun Shi, Jitao Zhang

Optics Express · 15.06.2026 · 34 (12) · 21322

DOI: 10.1364/oe.601790 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 01.06.2026. Verfasst von Chenjun Shi und 1 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Gefördert von: National Institutes of Health, U.S. National Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Confocal Brillouin microscopy enables high-resolution mechanical imaging but has low acquisition speed, partly due to its pixel-by-pixel mapping strategy. Line-scanning Brillouin microscopy (LSBM) significantly improves imaging speed by utilizing a multiplexing approach. However, the current method is limited to a single-stage virtually imaged phased array (VIPA) spectrometer with insufficient capability of suppressing noise. Consequently, an absorptive gas chamber is often used to help reject excessive elastically scattered light. This approach requires specific tunable laser sources whose frequencies (e.g., around 780 nm) are locked to the absorption line of the gas chamber. Here, we developed a multiplexed Brillouin spectrometer for LSBM that increased the noise suppression to 57 dB without using any gas chamber. This is achieved by cascading two VIPA etalons with parallel dispersion axes in the spectrometer, where the first VIPA acts as a band-pass filter and the second as a spectrum analyzer. We demonstrated its performance by acquiring Brillouin images of bio-printed phantoms with an inverted co-axial LSBM. This gas-chamber-free approach can expand the implementation of LSBM to other wavelengths where Brillouin scattering is more efficient and commercial laser sources are readily available.

Förderung

  • National Institutes of Health
  • U.S. National Science Foundation

Zitieren

APA

Shi, C., & Zhang, J. (2026). Line-scanning Brillouin microscopy with multiplexed two-stage VIPA spectrometer. Optics Express, 34(12), 21322. https://doi.org/10.1364/oe.601790

Vancouver

Shi C, Zhang J. Line-scanning Brillouin microscopy with multiplexed two-stage VIPA spectrometer. Optics Express. 2026;34(12):21322. doi:10.1364/oe.601790

BibTeX
@article{Shi2026,
  author = {Shi, Chenjun and Zhang, Jitao},
  title = {Line-scanning Brillouin microscopy with multiplexed two-stage VIPA spectrometer},
  journal = {Optics Express},
  year = {2026},
  volume = {34},
  number = {12},
  pages = {21322},
  doi = {10.1364/oe.601790}
}