Enhanced phase sensitivity of the Mach-Zehnder-type phase-shifting interferometry with single-intensity and difference-intensity detection
Optics Express · 10.08.2026 · 34 (16) · 30542
DOI: 10.1364/oe.600876 ↗Kurz gefasst
Fachartikel in der Zeitschrift Optics Express, online erschienen am 07.08.2026. Verfasst von Huanrong He und 1 weiteren Autor:innen. Die Arbeit nennt 49 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Kunming University of Science and Technology, Yunnan Provincial Science and Technology Department.
Abstract (Originalsprache)
Phase-shifting interferometry (PSI) promises excellent performance for quantitative phase measurement. However, the PSI is commonly realized by utilizing the Mach-Zehnder interferometer (MZI) fed with classical resources, and hence its phase sensitivity is hindered by the photon shot noise. In this paper, we propose to introduce specific phase-shifting algorithms into the well-established quantum-enhanced MZI, seeded by coherent and squeezed vacuum states and followed by single-mode intensity detection and difference intensity detection, to achieve quantitative phase measurement with sensitivity beyond that achieved by the corresponding Mach-Zehnder-type PSI with classical input. We show that when the average photon number of the coherent state is dominant, the optimal phase sensitivity of the Mach-Zehnder-type PSI with coherent plus squeezed vacuum input is better than the phase sensitivity of the Mach-Zehnder-type PSI with single coherent input under the same phase-sensing intensity condition in both of detection setups. We also show that for the typical MZI seeded with a high-power coherent state and a finitely squeezed vacuum state, the combination of intensity detection and phase-shifting algorithm can still improve the sensitivity of quantitative phase measurement. Furthermore, we derive the phase sensitivity of the fixed MZI as well as the quantum Cramér-Rao bound for two detection schemes. Finally, we explore the impacts of photon losses on the phase sensitivity enhancements of the Mach-Zehnder-type PSI and the fixed MZI in the high-intensity regime for each detection setup. The robustness to losses is compared between the Mach-Zehnder-type PSI and the fixed MZI. Our results may be helpful to promote the exploration of quantum-enhanced quantitative phase sensing.
Förderung
- National Natural Science Foundation of China
- Kunming University of Science and Technology
- Yunnan Provincial Science and Technology Department
Zitieren
APA
He, H., & Zhang, Y. (2026). Enhanced phase sensitivity of the Mach-Zehnder-type phase-shifting interferometry with single-intensity and difference-intensity detection. Optics Express, 34(16), 30542. https://doi.org/10.1364/oe.600876
Vancouver
He H, Zhang Y. Enhanced phase sensitivity of the Mach-Zehnder-type phase-shifting interferometry with single-intensity and difference-intensity detection. Optics Express. 2026;34(16):30542. doi:10.1364/oe.600876
BibTeX
@article{He2026,
author = {He, Huanrong and Zhang, Yaping},
title = {Enhanced phase sensitivity of the Mach-Zehnder-type phase-shifting interferometry with single-intensity and difference-intensity detection},
journal = {Optics Express},
year = {2026},
volume = {34},
number = {16},
pages = {30542},
doi = {10.1364/oe.600876}
}
EUVIMED