EUVIMEDEUVIMED entdecken
Crossref

Equal-phase resampling with periodic error suppression in swept-source interferometry under non-ideal I/Q demodulation

Hu Peng, Junkang Guo, Yuan Cao, Yueyang Liu, Weijin Meng, Zhigang Liu

Optics Express · 04.05.2026 · 34 (9) · 16102

DOI: 10.1364/oe.598982 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 21.04.2026. Verfasst von Hu Peng und 5 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Equal-phase resampling is a key technique for compensating laser sweep nonlinearity in swept-source interferometry. Phase extraction based on optical I/Q demodulation avoids complex global computations, offering a highly promising approach for low-latency resampling. However, practical wideband 90 ∘ hybrids inevitably suffer from amplitude mismatch and quadrature phase deviation. Such non-ideal I/Q demodulation introduces a phase-dependent ripple that severely perturbs the resampling grid, elevates spurs/sidelobes, and degrades spectral focusing. In this paper, we propose an equal-phase resampling method named PESR (Periodic Error Suppressed Resampling), which remains highly reliable even under severe I/Q imbalance (including hardware band mismatch). Without relying on conventional small-signal approximations, we theoretically prove that the arctangent demodulation error induced by quadrature errors has an intrinsic π -periodic component in the phase domain. Exploiting this property, we propose a “residual-phase-error filtering” strategy that effectively suppresses the periodic ripple while perfectly preserving the slow-varying phase trend dictating the resampling scale. Simulations not only verify this π -periodic characteristic but also reveal why directly applying a low-pass filter to the total phase introduces resampling scale bias. Experiments on a swept-source interferometric ranging platform demonstrate that, under massive quadrature errors, PESR suppresses the sidelobes of the single-sweep spectrum to approximately −25.5 dBc; in point-ranging evaluations, it achieves a sub-3- µ m RMS accuracy and an ultra-high measurement repeatability (MeanSTD) of 0.09~ µ m. Furthermore, PESR relaxes the reliance of traditional methods on a long auxiliary optical path difference, providing a robust and efficient solution for practical sweep nonlinearity correction and high-stability metrology.

Förderung

  • National Natural Science Foundation of China
  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Peng, H., Guo, J., Cao, Y., Liu, Y., Meng, W., & Liu, Z. (2026). Equal-phase resampling with periodic error suppression in swept-source interferometry under non-ideal I/Q demodulation. Optics Express, 34(9), 16102. https://doi.org/10.1364/oe.598982

Vancouver

Peng H, Guo J, Cao Y, Liu Y, Meng W, Liu Z. Equal-phase resampling with periodic error suppression in swept-source interferometry under non-ideal I/Q demodulation. Optics Express. 2026;34(9):16102. doi:10.1364/oe.598982

BibTeX
@article{Peng2026,
  author = {Peng, Hu and Guo, Junkang and Cao, Yuan and Liu, Yueyang and Meng, Weijin and Liu, Zhigang},
  title = {Equal-phase resampling with periodic error suppression in swept-source interferometry under non-ideal I/Q demodulation},
  journal = {Optics Express},
  year = {2026},
  volume = {34},
  number = {9},
  pages = {16102},
  doi = {10.1364/oe.598982}
}
Kostenlos starten →