EUVIMEDEUVIMED entdecken
Crossref

Mitigating depth-of-field limitations in high-resolution ptychographic X-ray tomography

Jingcheng Xiao, Nuo Chen, Enci Zhang, Hongyu Chen, Bo He, Xinye Yuan, Difei Zhang, Pingping Wen, Jianhua Zhang, Huaidong Jiang

Optics Express · 10.08.2026 · 34 (16) · 28959

DOI: 10.1364/oe.597588 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 28.07.2026. Verfasst von Jingcheng Xiao und 9 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China, Basic Research Program Based on Major Scientific Infrastructures, CAS.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

X-ray ptychographic tomography enables quantitative 3D imaging at nanometer resolution, but the limited depth of field causes out-of-focus artifacts in 2D reconstructions of extended samples, restricting the range of projection angles and reducing the quality of the reconstructed volume. Here, we present an imaging-plane-optimized ptychographic tomography method that corrects out-of-focus artefacts by optimizing the effective propagation distance during reconstruction. Both simulations and experiments show improved 2D image quality. Applied to tomography data, the method improves the quality of high-tilt projections and expands the angular range usable for reconstruction, thereby reducing axial elongation caused by the missing wedge. In the demonstrated macrophage dataset, this enables visualization of labeled intracellular structures and measurement of the distance between the silver label surface and the mitochondrion surface.

Förderung

  • National Natural Science Foundation of China
  • National Key Research and Development Program of China
  • Basic Research Program Based on Major Scientific Infrastructures, CAS

Zitieren

APA

Xiao, J., Chen, N., Zhang, E., Chen, H., He, B., Yuan, X., Zhang, D., Wen, P., Zhang, J., & Jiang, H. (2026). Mitigating depth-of-field limitations in high-resolution ptychographic X-ray tomography. Optics Express, 34(16), 28959. https://doi.org/10.1364/oe.597588

Vancouver

Xiao J, Chen N, Zhang E, Chen H, He B, Yuan X, et al. Mitigating depth-of-field limitations in high-resolution ptychographic X-ray tomography. Optics Express. 2026;34(16):28959. doi:10.1364/oe.597588

BibTeX
@article{Xiao2026,
  author = {Xiao, Jingcheng and Chen, Nuo and Zhang, Enci and Chen, Hongyu and He, Bo and Yuan, Xinye and Zhang, Difei and Wen, Pingping and Zhang, Jianhua and Jiang, Huaidong},
  title = {Mitigating depth-of-field limitations in high-resolution ptychographic X-ray tomography},
  journal = {Optics Express},
  year = {2026},
  volume = {34},
  number = {16},
  pages = {28959},
  doi = {10.1364/oe.597588}
}
Kostenlos starten →