Dual-frequency differential coupling Fabry-Perot interferometric displacement measurement achieves picometer accuracy in air
Optics Express · 23.03.2026 · 34 (6) · 10445
DOI: 10.1364/oe.579411 ↗Kurz gefasst
Fachartikel in der Zeitschrift Optics Express, online erschienen am 16.03.2026. Verfasst von Jianjun Cui und 3 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Science and Technology Plan Projects of Tibet Autonomous Region, Research projects in Key Scientific Field of NIM.
Abstract (Originalsprache)
A differential coupling Fabry-Perot (F-P) interferometric measurement method based on dual frequency-stabilized lasers is proposed, and a corresponding displacement measurement device is constructed. Displacement measurement with picometer-level accuracy is achieved in an air environment. This method subverts the traditional mindset that F-P interferometric displacement measurement requires optical frequency tuning; moreover, it only needs a dual-frequency laser with a frequency stability of the order of 10 −8 (whereas traditional methods require frequency measurement accuracy better than 10 −12 ) to achieve a displacement measurement resolution of 0.36 pm. Experimental results demonstrate that the measurement repeatability of this device reaches 28 pm in air, with the measurement stability better than ±23 pm. This measurement method has broad application prospects in the fields of metrological science and precision engineering.
Förderung
- National Key Research and Development Program of China
- Science and Technology Plan Projects of Tibet Autonomous Region
- Research projects in Key Scientific Field of NIM
Zitieren
APA
Cui, J., Zeng, D., Chen, K., & Yang, Z. (2026). Dual-frequency differential coupling Fabry-Perot interferometric displacement measurement achieves picometer accuracy in air. Optics Express, 34(6), 10445. https://doi.org/10.1364/oe.579411
Vancouver
Cui J, Zeng D, Chen K, Yang Z. Dual-frequency differential coupling Fabry-Perot interferometric displacement measurement achieves picometer accuracy in air. Optics Express. 2026;34(6):10445. doi:10.1364/oe.579411
BibTeX
@article{Cui2026,
author = {Cui, Jianjun and Zeng, Depei and Chen, Kai and Yang, Zhijun},
title = {Dual-frequency differential coupling Fabry-Perot interferometric displacement measurement achieves picometer accuracy in air},
journal = {Optics Express},
year = {2026},
volume = {34},
number = {6},
pages = {10445},
doi = {10.1364/oe.579411}
}
EUVIMED