Experimental comparison of X-ray ptychographic and holographic nanotomography of metal-stained neuronal tissue
Optics Express · 2025
DOI: 10.1364/oe.563186 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Optics Express, 2025. Verfasst von Alexandra Pacureanu und 11 weiteren Autor:innen. Hauptthemen laut MEDLINE: Holography, Neurons, Nanotechnology. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, Horizon 2020 Framework Programme, Engineering and Physical Sciences Research Council.
Abstract (Originalsprache)
Hard X-ray nanotomography is a promising technology for nondestructive imaging of biological tissues with three-dimensional isotropic resolution. The implementation of fourth-generation synchrotron sources brings coherent X-ray microscopy to the central stage and fosters further development of this class of techniques. Here, we present an experimental comparison of X-ray near-field ptychography and X-ray holography, two high-resolution X-ray microscopy techniques applied under cryogenic conditions to the exact same sample at two different synchrotron sources. Using a heavy-metal-stained, resin-embedded brain tissue sample, we obtain similar contrast and spatial resolutions at equivalent radiation doses with these two approaches. We discuss the current benefits and limitations of the two methods. These results provide a basis for developments in X-ray microscopy of biological samples at present and future beamlines of fourth-generation synchrotron sources.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- Wellcome Trust
- Horizon 2020 Framework Programme
- Engineering and Physical Sciences Research Council
- European Commission
- Medical Research Council
- Cancer Research UK
Zitieren
APA
Pacureanu, A., Thies, T., Bosch, C., Holler, M., Guizar-Sicairos, M., Müller, E., Reuteler, J., Karpov, D., Schaefer, A. T., Cloetens, P., Menzel, A., & Diaz, A. (2025). Experimental comparison of X-ray ptychographic and holographic nanotomography of metal-stained neuronal tissue. Optics Express. https://doi.org/10.1364/oe.563186
Vancouver
Pacureanu A, Thies T, Bosch C, Holler M, Guizar-Sicairos M, Müller E, et al. Experimental comparison of X-ray ptychographic and holographic nanotomography of metal-stained neuronal tissue. Optics Express. 2025. doi:10.1364/oe.563186
BibTeX
@article{Pacureanu2025,
author = {Pacureanu, Alexandra and Thies, Thomas and Bosch, Carles and Holler, Mirko and Guizar-Sicairos, Manuel and Müller, Elisabeth and Reuteler, Joakim and Karpov, Dmitry and Schaefer, Andreas T and Cloetens, Peter and Menzel, Andreas and Diaz, Ana},
title = {Experimental comparison of X-ray ptychographic and holographic nanotomography of metal-stained neuronal tissue},
journal = {Optics Express},
year = {2025},
doi = {10.1364/oe.563186}
}
EUVIMED