Ppb detection level’s hydrogen sensor using a SPR grating in the triggered switching configuration
Optics Express · 14.07.2025 · 33 (14) · 29648
DOI: 10.1364/oe.561549 ↗Kurz gefasst
Fachartikel in der Zeitschrift Optics Express, online erschienen am 07.07.2025. Verfasst von Pascal Giraud und 13 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 86 Literaturangaben. Gefördert von: Région Auvergne-Rhône-Alpes, Agence Nationale de la Recherche, Manutech SLEIGHT.
Abstract (Originalsprache)
An optical plasmonic hydrogen sensor is proposed, based on what we believe to be a novel configuration named plasmon-triggered switching. This configuration, involving two propagative orders diffracted by a deep metallic grating combined to a hydrogen-sensitive layer, is capable of measuring hydrogen concentrations. The two diffracted orders enable a differential measurement, which estimates a change of refractive index through evolution of the relative diffraction efficiency of each order at fixed wavelength and fixed angle, while cancelling any drift of the input laser source and other disturbances and allowing both a high sensitivity and a very low limit of detection (LOD). Experimental results, using a simple implementation involving one laser and two detectors, demonstrate a LOD without any signal post-processing, below 0.2 ppm (2.10 −5 % Vol) in filtered air, are in good agreement with simulations and exhibit very good repeatability. The proposed setup represents a very promising, compact and cost-efficient approach to real-time hydrogen sensing using a thin H 2 sensitive and selective palladium thin layer deposited on a gold grating for highly sensitive plasmon coupling.
Förderung
- Région Auvergne-Rhône-Alpes
- Agence Nationale de la Recherche
- Manutech SLEIGHT
Zitieren
APA
Giraud, P., Varenne, C., Brunet, J., Ndiaye, A., Verrier, I., Bruhier, H., Meyer, A., Girault, I., Arnould, F., Celle, F., Pacha, S. R., Gaté, V., Turover, D., & Jourlin, Y. (2025). Ppb detection level’s hydrogen sensor using a SPR grating in the triggered switching configuration. Optics Express, 33(14), 29648. https://doi.org/10.1364/oe.561549
Vancouver
Giraud P, Varenne C, Brunet J, Ndiaye A, Verrier I, Bruhier H, et al. Ppb detection level’s hydrogen sensor using a SPR grating in the triggered switching configuration. Optics Express. 2025;33(14):29648. doi:10.1364/oe.561549
BibTeX
@article{Giraud2025,
author = {Giraud, Pascal and Varenne, Christelle and Brunet, Jérôme and Ndiaye, Amadou and Verrier, Isabelle and Bruhier, Hugo and Meyer, Arnaud and Girault, Irvin and Arnould, Frédéric and Celle, Frédéric and Pacha, Salma Rajab and Gaté, Valentin and Turover, Daniel and Jourlin, Yves},
title = {Ppb detection level’s hydrogen sensor using a SPR grating in the triggered switching configuration},
journal = {Optics Express},
year = {2025},
volume = {33},
number = {14},
pages = {29648},
doi = {10.1364/oe.561549}
}
EUVIMED