EUVIMEDEUVIMED entdecken
Crossref

Temperature-compensated fiber optic hydrogen sensing with an in-fiber Fabry-Perot etalon and a Pd:Ni-coated cavity

Fabian Buchfellner, Alexander Roehrl, Minghong Yang, Alexander W. Koch, Johannes Roths

Optics Express · 16.12.2024 · 32 (26) · 46353

DOI: 10.1364/oe.543484 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 06.12.2024. Verfasst von Fabian Buchfellner und 4 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Deutsche Forschungsgemeinschaft, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents an in-situ temperature-decoupled sensor platform utilizing an in-fiber Fabry-Perot (FP) etalon made of two fiber Bragg gratings (FBGs) for simultaneous hydrogen concentration and temperature sensing. The platform’s key feature is a palladium-alloy-coated fiber section between the FBGs, while the FBGs themselves remain without coating. This design shifts the FP transmission fringes due to hydrogen-induced strain and temperature. In contrast, the envelope function induced by the FBG spectra shifts only with temperature, enabling intra-spectral referencing of the fringe wavelength to the envelope vertex wavelength and thereby compensating for temperature effects. This work discusses a fully zero-point-referenced sensor calibration for simultaneous hydrogen and temperature monitoring. Hydrogen calibration demonstrated precise measurement of concentrations ranging from 500 to 20,000 ppm(H 2 ) in a temperature range of 20 ∘ C to 50 ∘ C. Utilizing an iterative matrix algorithm, the non-linear hydrogen response was linearized and temperature cross-sensitivity was almost completely decoupled, leading to the representation of hydrogen concentrations with standard errors of the mean of 4.3% at repeated 1,000 ppm cycles, 2.8% at repeated 10,000 ppm cycles, and temperature measurement uncertainties of ±0.2 ∘ C. This proof-of-concept demonstrates the detection of low hydrogen quantities without distraction from temperature and thereby opens the path for fiber optic hydrogen sensing applications outside laboratories.

Förderung

  • Deutsche Forschungsgemeinschaft
  • National Natural Science Foundation of China

Zitieren

APA

Buchfellner, F., Roehrl, A., Yang, M., Koch, A. W., & Roths, J. (2024). Temperature-compensated fiber optic hydrogen sensing with an in-fiber Fabry-Perot etalon and a Pd:Ni-coated cavity. Optics Express, 32(26), 46353. https://doi.org/10.1364/oe.543484

Vancouver

Buchfellner F, Roehrl A, Yang M, Koch AW, Roths J. Temperature-compensated fiber optic hydrogen sensing with an in-fiber Fabry-Perot etalon and a Pd:Ni-coated cavity. Optics Express. 2024;32(26):46353. doi:10.1364/oe.543484

BibTeX
@article{Buchfellner2024,
  author = {Buchfellner, Fabian and Roehrl, Alexander and Yang, Minghong and Koch, Alexander W. and Roths, Johannes},
  title = {Temperature-compensated fiber optic hydrogen sensing with an in-fiber Fabry-Perot etalon and a Pd:Ni-coated cavity},
  journal = {Optics Express},
  year = {2024},
  volume = {32},
  number = {26},
  pages = {46353},
  doi = {10.1364/oe.543484}
}