EUVIMEDEUVIMED entdecken
Crossref

Improved thermometry via luminescence lifetime ratio of Er 3+ and Tm 3+ operated in the biological window

Syed Muhammad Ehtesham Raza, Xinyu Wang, Yuxin Jin, Ye Tian, Ci Wang, Jing Ren, Lu Liu, Jianzhong Zhang

Optics Express · 2024

DOI: 10.1364/oe.534968 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, 2024. Verfasst von Syed Muhammad Ehtesham Raza und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Erbium, Thermometry, Thulium, Luminescent Measurements. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The luminescent intensity ratio of Lanthanide-doped nanocrystals has been widely used for non-contact thermometry but is still facing difficulties in biological applications due to spectrum distortion caused by tissues. Lifetime-based thermometry is the best alternative to other typical thermometry methods. However, its main drawback is the limited sensitivity. This paper introduces an innovative method known as luminescence lifetime ratio, which enhances luminescence thermometry by combining two emission bands with opposite decay behaviors with temperature. As a proof of concept, a core-shell structure separately containing Tm 3+ and Er 3+ was synthesized and exhibited two strong emission bands centered at 800 nm and 1530 nm, which are located in the NIR-I and NIR-III biological windows. The commonly used LIR thermometer, an Er/Yb co-doped NaYF 4 sample, was also synthesized for comparison. By using chicken tissues of varying thicknesses (1 mm and 3 mm), it was revealed that the deep-tissue penetration and accuracy in biological environments of luminescence lifetime ratio are evidently improved than the widely-used technique of luminescence intensity ratio, although the relative sensitivity of is not much better. In summary, the luminescence lifetime ratio technique enables novel and more accurate temperature sensing within the wavelength range that is suitable for biological applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ErbiumThermometryThuliumLuminescent MeasurementsAnimalsChickensLuminescenceNanoparticles

Substanzen

ErbiumThulium

Förderung

  • Fundamental Research Funds for the Central Universities
  • National Natural Science Foundation of China

Zitieren

APA

Ehtesham Raza, S. M., Wang, X., Jin, Y., Tian, Y., Wang, C., Ren, J., Liu, L., & Zhang, J. (2024). Improved thermometry via luminescence lifetime ratio of Er 3+ and Tm 3+ operated in the biological window. Optics Express. https://doi.org/10.1364/oe.534968

Vancouver

Ehtesham Raza SM, Wang X, Jin Y, Tian Y, Wang C, Ren J, et al. Improved thermometry via luminescence lifetime ratio of Er 3+ and Tm 3+ operated in the biological window. Optics Express. 2024. doi:10.1364/oe.534968

BibTeX
@article{EhteshamRaza2024,
  author = {Ehtesham Raza, Syed Muhammad and Wang, Xinyu and Jin, Yuxin and Tian, Ye and Wang, Ci and Ren, Jing and Liu, Lu and Zhang, Jianzhong},
  title = {Improved thermometry via luminescence lifetime ratio of Er 3+ and Tm 3+ operated in the biological window},
  journal = {Optics Express},
  year = {2024},
  doi = {10.1364/oe.534968}
}
Kostenlos starten →