EUVIMEDEUVIMED entdecken
Crossref

Numerical analysis of a single channel exposed core elliptical shaped PCF based highly sensitive SPR sensor for wide RI sensing

Israt Jahan Trisha, Abdul Karim Patwary, Md Abu Sayem, Afiquer Rahman, Md Rakib Hossain, Md Aslam Mollah

Optics Express · 01.07.2024 · 32 (14) · 25472

DOI: 10.1364/oe.530030 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 28.06.2024. Verfasst von Israt Jahan Trisha und 5 weiteren Autor:innen. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a numerical study of a highly sensitive photonic crystal fiber (PCF) surface plasmon resonance (SPR) sensor capable of detecting five types of cancer and bacterial contamination in water. By precisely arranging only two air holes in a single channel of an elliptical-shaped PCF, the sensor maximizes interaction between core-guided modes and surface plasmon polaritons (SPP) along the fiber. Evaluation using COMSOL Multiphysics simulation software, based on finite element method (FEM), demonstrates outstanding sensor performance across a wide refractive index (RI) range (1.33 to 1.43). With a maximum wavelength sensitivity (WS) of 188,000 nm/RIU and amplitude sensitivity (AS) of -22,377.99 RIU −1 , the sensor achieveStructural Design and Methodologys a sensor resolution (SR) of 5.3191 × 10 −7 RIU and figure of merit (FOM) of 854.55 RIU −1 . Notably, it exhibits AS and WS values tailored for specific cancer cell types and water contamination. These results endorse the sensor’s potential in diverse biological and molecular analyte RI detection applications within the visible to near-infrared (VNIR) range (0.55 to 4 µm), offering high sensitivity, affordability, wide sensing range, good linearity, low propagation loss, and simplicity in construction.

Zitieren

APA

Trisha, I. J., Patwary, A. K., Sayem, M. A., Rahman, A., Hossain, M. R., & Mollah, M. A. (2024). Numerical analysis of a single channel exposed core elliptical shaped PCF based highly sensitive SPR sensor for wide RI sensing. Optics Express, 32(14), 25472. https://doi.org/10.1364/oe.530030

Vancouver

Trisha IJ, Patwary AK, Sayem MA, Rahman A, Hossain MR, Mollah MA. Numerical analysis of a single channel exposed core elliptical shaped PCF based highly sensitive SPR sensor for wide RI sensing. Optics Express. 2024;32(14):25472. doi:10.1364/oe.530030

BibTeX
@article{Trisha2024,
  author = {Trisha, Israt Jahan and Patwary, Abdul Karim and Sayem, Md Abu and Rahman, Afiquer and Hossain, Md Rakib and Mollah, Md Aslam},
  title = {Numerical analysis of a single channel exposed core elliptical shaped PCF based highly sensitive SPR sensor for wide RI sensing},
  journal = {Optics Express},
  year = {2024},
  volume = {32},
  number = {14},
  pages = {25472},
  doi = {10.1364/oe.530030}
}
Kostenlos starten →