EUVIMEDEUVIMED entdecken
Crossref

Systematic error calibration of vertical dynamic interferometer with sloshing liquid plane

Chenhui Hu, Donghui Zheng, Lei Chen

Optics Express · 17.06.2024 · 32 (13) · 23070

DOI: 10.1364/oe.528883 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 07.06.2024. Verfasst von Chenhui Hu und 2 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China, Natural Science Foundation of Jiangsu Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Liquid mirror can calibrate the interferometer system error by measuring the surface of a steady-state, high-viscosity liquid; however, strict environmental safeguards are typically required. To address this problem, we propose a new liquid mirror method based on liquid micro-amplitude sloshing to calibrate dynamic interferometer system error. According to the multimodal analysis method of fluid finite amplitude sloshing, the liquid surface sloshing surface was modeled and analyzed, a time dimensional mean model was established, and the minimum sampling time was calculated. Finally, the error of the liquid surface sloshing was reduced by time averaging to realize the absolute calibration of the dynamic interferometer's systematic error. According to the proposed minimum sampling time theory, when the mean processing time is greater than the minimum sampling time, the error in the sloshing liquid surface can be controlled to within λ/100. The method’s correctness is proven through an experimental comparison of different calibration methods.

Förderung

  • Fundamental Research Funds for the Central Universities
  • National Natural Science Foundation of China
  • Natural Science Foundation of Jiangsu Province
  • Postgraduate Research & Practice Innovation Program of Jiangsu Province
  • China Scholarship Council

Zitieren

APA

Hu, C., Zheng, D., & Chen, L. (2024). Systematic error calibration of vertical dynamic interferometer with sloshing liquid plane. Optics Express, 32(13), 23070. https://doi.org/10.1364/oe.528883

Vancouver

Hu C, Zheng D, Chen L. Systematic error calibration of vertical dynamic interferometer with sloshing liquid plane. Optics Express. 2024;32(13):23070. doi:10.1364/oe.528883

BibTeX
@article{Hu2024,
  author = {Hu, Chenhui and Zheng, Donghui and Chen, Lei},
  title = {Systematic error calibration of vertical dynamic interferometer with sloshing liquid plane},
  journal = {Optics Express},
  year = {2024},
  volume = {32},
  number = {13},
  pages = {23070},
  doi = {10.1364/oe.528883}
}
Kostenlos starten →