Fachartikel in der Zeitschrift Optics Express, online erschienen am 12.06.2024. Verfasst von William Newman und 7 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Facilities Council.
Abstract (Originalsprache)
High-resolution cross-dispersion spectrographs are widely used in spectroscopy, but the two-dimensional format of the spectrum requires sophisticated calibration, conventionally performed by illuminating the instrument with a broadband hollow-cathode lamp and cross-referencing the result to an emission-line atlas. Here, we introduce a new technique to completely calibrate a high-resolution echelle spectrograph using only a laser frequency comb. Selected individual comb lines are removed from a broadband 20 GHz laser frequency comb—revealing their exact location in the spectrograph echellogram—and wavelength-tagged with sub-fm accuracy. In a complementary procedure, the comb is reduced to contain one line per echellogram order, enabling the spectrograph’s free spectral range to be visualized and the exact concatenation between orders to be determined. In this way, the complete calibration of the high-resolution spectrograph is achieved using only a laser frequency comb, directly providing GPS-referenced accuracy without the need to bootstrap the calibration by indexing the comb modes using a broadband atomic-line source.
Förderung
- Science and Technology Facilities Council
Zitieren
APA
Newman, W., Charsley, J. M., Slattery, J., Mitchell, T., Dadi, K., Cheng, Y. S., McCracken, R. A., & Reid, D. T. (2024). Cross-dispersion spectrograph calibration using only a laser frequency comb. Optics Express, 32(13), 23617. https://doi.org/10.1364/oe.524523
Vancouver
Newman W, Charsley JM, Slattery J, Mitchell T, Dadi K, Cheng YS, et al. Cross-dispersion spectrograph calibration using only a laser frequency comb. Optics Express. 2024;32(13):23617. doi:10.1364/oe.524523
BibTeX
@article{Newman2024,
author = {Newman, William and Charsley, Jake M and Slattery, Jamie and Mitchell, Toby and Dadi, Kamalesh and Cheng, Yuk Shan and McCracken, Richard A and Reid, Derryck T},
title = {Cross-dispersion spectrograph calibration using only a laser frequency comb},
journal = {Optics Express},
year = {2024},
volume = {32},
number = {13},
pages = {23617},
doi = {10.1364/oe.524523}
}