On-chip Mach-Zehnder interferometer sensor with a double-slot hybrid plasmonic waveguide for high-sensitivity hydrogen detection
Optics Express · 20.11.2023 · 31 (24) · 39500
DOI: 10.1364/oe.504859 ↗Kurz gefasst
Fachartikel in der Zeitschrift Optics Express, online erschienen am 06.11.2023. Verfasst von Guanjingyun Wang und 1 weiteren Autor:innen. Die Arbeit wurde bisher 104-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Chongqing Municipal Education Commission, Chongqing Science and Technology Bureau.
Abstract (Originalsprache)
An on-chip Mach-Zehnder interferometer (MZI) hydrogen sensor, applying a double-slot hybrid plasmonic (DSHP) waveguide composed of a Si waveguide and two Pd disks on both sides as the sensing arm, is designed. The optical confinement factor of the sensing area can be up to 87%. For the MZI hydrogen sensor with a DSHP waveguide of 14 µm, the sensitivity can be as high as 11.935 nm/%, corresponding to a free spectral range (FSR) of 15 nm. Furthermore, the sensor sensitivity is influenced by the MZI structure parameters, which is highly adjustable. The extinction ratio of the interference spectra can reach over 30 dB. A feasible solution is provided in this paper for highly sensitive hydrogen detection.
Förderung
- National Natural Science Foundation of China
- Chongqing Municipal Education Commission
- Chongqing Science and Technology Bureau
- Joint Fund of Chongqing Municipal Education Commission and Science and Technology Bureau
- Chongqing University of Technology
Zitieren
APA
Wang, G., & Feng, W. (2023). On-chip Mach-Zehnder interferometer sensor with a double-slot hybrid plasmonic waveguide for high-sensitivity hydrogen detection. Optics Express, 31(24), 39500. https://doi.org/10.1364/oe.504859
Vancouver
Wang G, Feng W. On-chip Mach-Zehnder interferometer sensor with a double-slot hybrid plasmonic waveguide for high-sensitivity hydrogen detection. Optics Express. 2023;31(24):39500. doi:10.1364/oe.504859
BibTeX
@article{Wang2023,
author = {Wang, Guanjingyun and Feng, Wenlin},
title = {On-chip Mach-Zehnder interferometer sensor with a double-slot hybrid plasmonic waveguide for high-sensitivity hydrogen detection},
journal = {Optics Express},
year = {2023},
volume = {31},
number = {24},
pages = {39500},
doi = {10.1364/oe.504859}
}