EUVIMEDEUVIMED entdecken
Crossref

Midwave resonant cavity infrared detectors (RCIDs) with suppressed background noise

Chadwick L Canedy, Eric M Jackson, Richard L Espinola, Myron R Pauli, Jason M Auxier, Chul Soo Kim, Mijin Kim, Jill A Nolde, Chase T Ellis, Edward H Aifer, Igor Vurgaftman, Vijaysekhar Jayaraman und 4 weitere

Optics Express · 09.10.2023 · 31 (21) · 35225

DOI: 10.1364/oe.500125 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 05.10.2023. Verfasst von Chadwick L Canedy und 15 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Office of Naval Research, Army Research Office.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We report a resonant cavity infrared detector (RCID) with an InAsSb/InAs superlattice absorber with a thickness of only ≈ 100 nm, a 33-period GaAs/Al 0.92 Ga 0.08 As distributed Bragg reflector bottom mirror, and a Ge/SiO 2 /Ge top mirror. At a low bias voltage of 150 mV, the external quantum efficiency (EQE) reaches 58% at the resonance wavelength λ res ≈ 4.6 µm, with linewidth δλ = 19-27 nm. The thermal background current for a realistic system scenario with f/4 optic that views a 300 K scene is estimated by integrating the photocurrent generated by background spanning the entire mid-IR spectral band (3-5 µm). The resulting specific detectivity is a factor of 3 lower than for a state-of-the-art broadband HgCdTe device at 300 K, where dark current dominates the noise. However, at 125 K where the suppression of background noise becomes critical, the estimated specific detectivity D * of 5.5 × 10 12 cm Hz ½ /W is more than 3× higher. This occurs despite a non-optimal absorber cut-off that causes the EQE to decrease rapidly with decreasing temperature, e.g., to 33% at 125 K. The present RCID’s advantage over the broadband device depends critically on its low EQE at non-resonance wavelengths: ≤ 1% in the range 3.9-5.5 µm. Simulations using NRL MULTIBANDS indicate that impact ionization in the bottom contact and absorber layers dominates the dark current at near ambient temperatures. We expect future design modifications to substantially enhance D * throughout the investigated temperature range of 100-300 K.

Förderung

  • Office of Naval Research
  • Army Research Office

Zitieren

APA

Canedy, C. L., Jackson, E. M., Espinola, R. L., Pauli, M. R., Auxier, J. M., Kim, C. S., Kim, M., Nolde, J. A., Ellis, C. T., Aifer, E. H., Vurgaftman, I., Jayaraman, V., Kolasa, B., Marsland, R., Knipfer, B., & Meyer, J. R. (2023). Midwave resonant cavity infrared detectors (RCIDs) with suppressed background noise. Optics Express, 31(21), 35225. https://doi.org/10.1364/oe.500125

Vancouver

Canedy CL, Jackson EM, Espinola RL, Pauli MR, Auxier JM, Kim CS, et al. Midwave resonant cavity infrared detectors (RCIDs) with suppressed background noise. Optics Express. 2023;31(21):35225. doi:10.1364/oe.500125

BibTeX
@article{Canedy2023,
  author = {Canedy, Chadwick L and Jackson, Eric M and Espinola, Richard L and Pauli, Myron R and Auxier, Jason M and Kim, Chul Soo and Kim, Mijin and Nolde, Jill A and Ellis, Chase T and Aifer, Edward H and Vurgaftman, Igor and Jayaraman, Vijaysekhar and Kolasa, Borys and Marsland, Robert and Knipfer, Benjamin and Meyer, Jerry R},
  title = {Midwave resonant cavity infrared detectors (RCIDs) with suppressed background noise},
  journal = {Optics Express},
  year = {2023},
  volume = {31},
  number = {21},
  pages = {35225},
  doi = {10.1364/oe.500125}
}
Kostenlos starten →