EUVIMEDEUVIMED entdecken
Crossref

Fourier ptychographic topography

Hao Wang, Jiabei Zhu, Jangwoon Sung, Guorong Hu, Joseph Greene, Yunzhe Li, Seungbeom Park, Wookrae Kim, Myungjun Lee, Yusin Yang, Lei Tian

Optics Express · 27.03.2023 · 31 (7) · 11007

DOI: 10.1364/oe.481712 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 17.03.2023. Verfasst von Hao Wang und 10 weiteren Autor:innen. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Samsung.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Topography measurement is essential for surface characterization, semiconductor metrology, and inspection applications. To date, performing high-throughput and accurate topography remains challenging due to the trade-off between field-of-view (FOV) and spatial resolution. Here we demonstrate a novel topography technique based on the reflection-mode Fourier ptychographic microscopy, termed Fourier ptychograhpic topography (FPT). We show that FPT provides both a wide FOV and high resolution, and achieves nanoscale height reconstruction accuracy. Our FPT prototype is based on a custom-built computational microscope consisting of programmable brightfield and darkfield LED arrays. The topography reconstruction is performed by a sequential Gauss-Newton-based Fourier ptychographic phase retrieval algorithm augmented with total variation regularization. We achieve a synthetic numerical aperture (NA) of 0.84 and a diffraction-limited resolution of 750 nm, increasing the native objective NA (0.28) by 3×, across a 1.2 × 1.2 mm 2 FOV. We experimentally demonstrate the FPT on a variety of reflective samples with different patterned structures. The reconstructed resolution is validated on both amplitude and phase resolution test features. The accuracy of the reconstructed surface profile is benchmarked against high-resolution optical profilometry measurements. In addition, we show that the FPT provides robust surface profile reconstructions even on complex patterns with fine features that cannot be reliably measured by the standard optical profilometer. The spatial and temporal noise of our FPT system is characterized to be 0.529 nm and 0.027 nm, respectively.

Förderung

  • Samsung

Zitieren

APA

Wang, H., Zhu, J., Sung, J., Hu, G., Greene, J., Li, Y., Park, S., Kim, W., Lee, M., Yang, Y., & Tian, L. (2023). Fourier ptychographic topography. Optics Express, 31(7), 11007. https://doi.org/10.1364/oe.481712

Vancouver

Wang H, Zhu J, Sung J, Hu G, Greene J, Li Y, et al. Fourier ptychographic topography. Optics Express. 2023;31(7):11007. doi:10.1364/oe.481712

BibTeX
@article{Wang2023,
  author = {Wang, Hao and Zhu, Jiabei and Sung, Jangwoon and Hu, Guorong and Greene, Joseph and Li, Yunzhe and Park, Seungbeom and Kim, Wookrae and Lee, Myungjun and Yang, Yusin and Tian, Lei},
  title = {Fourier ptychographic topography},
  journal = {Optics Express},
  year = {2023},
  volume = {31},
  number = {7},
  pages = {11007},
  doi = {10.1364/oe.481712}
}
Kostenlos starten →