EUVIMEDEUVIMED entdecken
Crossref

Accurate and flexible calibration method for a 3D microscopic structured light system with telecentric imaging and Scheimpflug projection

Huiwen Deng, Pengyu Hu, Guofeng Zhang, Chengsheng Xia, Yindi Cai, Shuming Yang

Optics Express · 16.01.2023 · 31 (2) · 3092

DOI: 10.1364/oe.480333 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 11.01.2023. Verfasst von Huiwen Deng und 5 weiteren Autor:innen. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Science Fund for Distinguished Young Scholars, Key Research and Development Projects of Shaanxi Province, Open Project of Key Laboratory for Micro/Nano Technology and System, Dalian University of Technology, Liaoning Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

3D imaging and metrology of complex micro-structures is a critical task for precision manufacturing and inspection. In this paper, an accurate and flexible calibration method for 3D microscopic structured light system with telecentric imaging and Scheimpflug projector is proposed. Firstly, a fringe projection 3D microscopy (FP-3DM) system consisting of a telecentric camera and a Scheimpflug projector is developed, which can take full advantage of the depth of field (DOF) and increase the measurement depth range. Secondly, an accurate and flexible joint calibration method is proposed to calibrate the developed system, which utilizes the established pinhole imaging model and Scheimpflug distortion model to calibrate telecentric imaging, and fully considers the correction and error optimization of the Scheimpflug projection model. Meanwhile, the optimized local homography is calculated to obtain more accurate sub-pixel correspondence between the camera and the projector, and the perspective-n-point (PnP) method make the 3D coordinate estimation of the feature point more accurate. Finally, a prototype and a dedicated calibration program are developed to realize high-resolution and high-precision 3D imaging. The experimental results demonstrate that the re-projection error is less than 1 µm , and the 3D repeated measurement error based on feature fitting is less than 4 µm , within the calibrated volume of 10(H) mm × 50(W) mm × 40(D) mm .

Förderung

  • National Science Fund for Distinguished Young Scholars
  • Key Research and Development Projects of Shaanxi Province
  • Open Project of Key Laboratory for Micro/Nano Technology and System, Dalian University of Technology, Liaoning Province

Zitieren

APA

Deng, H., Hu, P., Zhang, G., Xia, C., Cai, Y., & Yang, S. (2023). Accurate and flexible calibration method for a 3D microscopic structured light system with telecentric imaging and Scheimpflug projection. Optics Express, 31(2), 3092. https://doi.org/10.1364/oe.480333

Vancouver

Deng H, Hu P, Zhang G, Xia C, Cai Y, Yang S. Accurate and flexible calibration method for a 3D microscopic structured light system with telecentric imaging and Scheimpflug projection. Optics Express. 2023;31(2):3092. doi:10.1364/oe.480333

BibTeX
@article{Deng2023,
  author = {Deng, Huiwen and Hu, Pengyu and Zhang, Guofeng and Xia, Chengsheng and Cai, Yindi and Yang, Shuming},
  title = {Accurate and flexible calibration method for a 3D microscopic structured light system with telecentric imaging and Scheimpflug projection},
  journal = {Optics Express},
  year = {2023},
  volume = {31},
  number = {2},
  pages = {3092},
  doi = {10.1364/oe.480333}
}
Kostenlos starten →