EUVIMEDEUVIMED entdecken
Crossref

Wavefront-preserved thermal–optical design of a high-heat-load grazing-incidence X-ray mirror

Zhen Wang iD, Fang Liu, Weizhen Lei, Xiaohao Dong iD, Yuzhu Wang, Yajun Tong

Journal of the Optical Society of America A · 01.11.2026 · 43 (11) · 1888

DOI: 10.1364/josaa.611622 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Optical Society of America A, online erschienen am 30.10.2026. Verfasst von Zhen Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center for Transformative Science, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai 201210, China. Die Arbeit nennt 31 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-repetition-rate X-ray free-electron laser facilities impose stringent requirements on the thermal stability and wavefront preservation of beamline mirrors. In this work, a coupled thermal–optical optimization method is developed for the first reflective mirror of the FEL-III beamline at the SHINE facility under an absorbed heat load of up to 11.12 W at a photon energy of 15 keV and a repetition rate of 200 kHz, with a peak absorbed power density of 0.0718W/mm 2 . The cooling length and cooling-groove distance from the optical surface are jointly optimized, and their effects on residual height error, slope error, and focal-plane Strehl ratio are evaluated using thermal–structural analysis and X-ray tracing. The results show that the mirror performance is governed by the coupled cooling geometry rather than by either parameter alone. Compared with the initial full-length cooling design, the optimized design reduces the RMS residual height error by 73.7% and the RMS slope error by 68.9%. The system-level Strehl ratio increases from 0.45 to 0.993, exceeding the target value of 0.96, while stray-light features are suppressed and a compact focal intensity distribution is recovered at the sample plane. These results demonstrate that deformation-based thermal optimization, when combined with system-level X-ray tracing, provides an effective thermal–optical design route for preserving wavefront quality in high-heat-load grazing-incidence X-ray optical systems.

Autor:innen und Institutionen

  • Center for Transformative Science, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai 201210, China.
  • Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201204, China.

ORCID-Profile: Zhen Wang, Xiaohao Dong

Zitieren

APA

Wang, Z., Liu, F., Lei, W., Dong, X., Wang, Y., & Tong, Y. (2026). Wavefront-preserved thermal–optical design of a high-heat-load grazing-incidence X-ray mirror. Journal of the Optical Society of America A, 43(11), 1888. https://doi.org/10.1364/josaa.611622

Vancouver

Wang Z, Liu F, Lei W, Dong X, Wang Y, Tong Y. Wavefront-preserved thermal–optical design of a high-heat-load grazing-incidence X-ray mirror. Journal of the Optical Society of America A. 2026;43(11):1888. doi:10.1364/josaa.611622

BibTeX
@article{Wang2026,
  author = {Wang, Zhen and Liu, Fang and Lei, Weizhen and Dong, Xiaohao and Wang, Yuzhu and Tong, Yajun},
  title = {Wavefront-preserved thermal–optical design of a high-heat-load grazing-incidence X-ray mirror},
  journal = {Journal of the Optical Society of America A},
  year = {2026},
  volume = {43},
  number = {11},
  pages = {1888},
  doi = {10.1364/josaa.611622}
}
Kostenlos starten →