Comparative study of aperture-induced aberrations in reflective and transmissive optical spectrometers using ZEMAX

Muddasir Naeem, Tayyab Imran

Journal of the Optical Society of America A · 01.08.2026 · 43 (8) · 1272

DOI: 10.1364/josaa.604734 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Optical Society of America A, online erschienen am 21.07.2026. Verfasst von Muddasir Naeem und 1 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a design-level comparison of aperture-induced imaging degradation in reflective and transmissive optical spectrometers using ZEMAX OpticStudio. Two representative grating-based spectrometer configurations were modeled and evaluated under identical input-aperture, wavelength, detector, and grating-order conditions while varying the entrance pinhole diameter from 5 to 100 µm. The optical response was assessed using complementary image-quality metrics, including geometric, Huygens, and diffraction modulation transfer functions, line spread function, edge spread function, FFT-derived spread functions, and detector-plane irradiance. The results show that increasing the input pinhole size systematically reduces modulation transfer, broadens the line and edge responses, and redistributes optical energy over a larger detector region, indicating a transition from an optics-limited response at small apertures to a source-size-limited response at larger apertures. Within the specific optical prescriptions considered here, the reflective configuration preserved modulation, edge sharpness, and detector-plane energy confinement more effectively than the simple singlet-lens transmissive configuration. The study establishes a direct design connection between entrance-aperture size, spatial-frequency response, spread-function broadening, and detector-plane energy confinement, providing practical guidance for compact spectrometer designs where resolution, throughput, and aberration tolerance must be balanced.

Zitieren

APA

Naeem, M., & Imran, T. (2026). Comparative study of aperture-induced aberrations in reflective and transmissive optical spectrometers using ZEMAX. Journal of the Optical Society of America A, 43(8), 1272. https://doi.org/10.1364/josaa.604734

Vancouver

Naeem M, Imran T. Comparative study of aperture-induced aberrations in reflective and transmissive optical spectrometers using ZEMAX. Journal of the Optical Society of America A. 2026;43(8):1272. doi:10.1364/josaa.604734

BibTeX
@article{Naeem2026,
  author = {Naeem, Muddasir and Imran, Tayyab},
  title = {Comparative study of aperture-induced aberrations in reflective and transmissive optical spectrometers using ZEMAX},
  journal = {Journal of the Optical Society of America A},
  year = {2026},
  volume = {43},
  number = {8},
  pages = {1272},
  doi = {10.1364/josaa.604734}
}
Kostenlos starten →