Unified variational framework for simultaneous correction of non-uniform sampling and diffraction-induced slope errors in coherence scanning interferometry
Journal of the Optical Society of America A · 01.08.2026 · 43 (8) · 1176
DOI: 10.1364/josaa.601571 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the Optical Society of America A, online erschienen am 10.07.2026. Verfasst von Yulan Chen und 4 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Gefördert von: Ministry of Science and Technology of the People’s Republic of China.
Abstract (Originalsprache)
Coherence scanning interferometry (CSI) enables non-contact surface measurement with high axial resolution, but its accuracy is degraded in practical complex-surface metrology by two coupled effects: vibration-induced non-uniform axial sampling and diffraction-induced slope/edge errors. Axial-position sensing can provide frame-wise scanning positions, but it does not correct the optical-transfer-function degradation caused by finite-aperture imaging. Conversely, conventional inverse filtering compensates for diffraction-related attenuation but usually assumes uniform axial sampling. This paper proposes a unified variational reconstruction framework that incorporates measured non-uniform axial positions into an NUFFT-based CSI forward model with sparse regularization. The proposed method jointly models non-uniform sampling and optical-transfer-function degradation, and is evaluated against uniform-sampling inverse filtering, non-uniform least-squares phase recovery, and a two-step adjoint-NUFFT/IF baseline. Numerical simulations demonstrate improved robustness under strong sampling non-uniformity, residual axial-position errors, detector noise, and varying spectral widths. For the tested step sample, the proposed method achieves a step-height error of 0.052 nm and suppresses directional batwing artifacts to approximately the nanometer level. GPU implementation on an NVIDIA RTX 5070 Ti processes a representative 400×400×500 volume in 8.929 s, with only about 12.5% overhead relative to the two-step adjoint-NUFFT/IF baseline. These results indicate that the proposed framework is promising for calibrated CSI systems with available frame-wise axial positions.
Förderung
- Ministry of Science and Technology of the People’s Republic of China
Zitieren
APA
Chen, Y., Liu, A., Hao, Y., He, J., & Zhang, W. (2026). Unified variational framework for simultaneous correction of non-uniform sampling and diffraction-induced slope errors in coherence scanning interferometry. Journal of the Optical Society of America A, 43(8), 1176. https://doi.org/10.1364/josaa.601571
Vancouver
Chen Y, Liu A, Hao Y, He J, Zhang W. Unified variational framework for simultaneous correction of non-uniform sampling and diffraction-induced slope errors in coherence scanning interferometry. Journal of the Optical Society of America A. 2026;43(8):1176. doi:10.1364/josaa.601571
BibTeX
@article{Chen2026,
author = {Chen, Yulan and Liu, Anqi and Hao, Yiwei and He, Jiaqi and Zhang, Wenxi},
title = {Unified variational framework for simultaneous correction of non-uniform sampling and diffraction-induced slope errors in coherence scanning interferometry},
journal = {Journal of the Optical Society of America A},
year = {2026},
volume = {43},
number = {8},
pages = {1176},
doi = {10.1364/josaa.601571}
}
EUVIMED