EUVIMEDEUVIMED entdecken
Crossref

Off-axis laser-radiation detection based on intensity interferometry: evaluation of signal and noise

Elizabeth Bleszynski, Marek Bleszynski, Thomas Jaroszewicz

Journal of the Optical Society of America A · 01.05.2026 · 43 (5) · 745

DOI: 10.1364/josaa.579005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Optical Society of America A, online erschienen am 16.04.2026. Verfasst von Elizabeth Bleszynski und 2 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Gefördert von: Air Force Office of Scientific Research, Office of Naval Research.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We present a method for detecting indirect, off-axis light radiated by a laser beam propagating in the atmosphere, in the presence of (primarily solar) background. Unlike in most existent methods, where laser light detection is based on its monochromaticity or intensity, the proposed approach uses a high degree of temporal coherence of laser radiation as the discriminating factor against potentially strong but very low-coherence background. The method also relies on intensity interferometry, rather than amplitude interferometry approaches frequently found in the literature. The analytic developments of this paper revolve around the evaluation of two quantities—the intensity correlation signal and its fluctuations (or noise)—envisaged as measures of the proposed coherence signature, designed to apply to both stationary and pulsed radiation. Reliable evaluation of the noise, due to strong statistical fluctuations of the high-temporal-coherence scattered field, is essential, as well as challenging, because of the presence of higher, up to the fourth order, moments of the measured optical intensities. We calculated full effects of statistical fluctuations of the laser- and background-related radiation and established the optimal detector parameters maximizing the obtained signal-to-noise value. We show that the signal-to-noise ratio may be on the order of 10 for a single recorded pulse and, in practically relevant case of a train of pulses, increases as the square-root of the number of pulses in the sequence. While the proposed approach has direct applications in the development of laser warning systems, closely related techniques should be applicable in active imaging, particularly in LiDAR systems operating in the presence of strong background.

Förderung

  • Air Force Office of Scientific Research
  • Office of Naval Research

Zitieren

APA

Bleszynski, E., Bleszynski, M., & Jaroszewicz, T. (2026). Off-axis laser-radiation detection based on intensity interferometry: evaluation of signal and noise. Journal of the Optical Society of America A, 43(5), 745. https://doi.org/10.1364/josaa.579005

Vancouver

Bleszynski E, Bleszynski M, Jaroszewicz T. Off-axis laser-radiation detection based on intensity interferometry: evaluation of signal and noise. Journal of the Optical Society of America A. 2026;43(5):745. doi:10.1364/josaa.579005

BibTeX
@article{Bleszynski2026,
  author = {Bleszynski, Elizabeth and Bleszynski, Marek and Jaroszewicz, Thomas},
  title = {Off-axis laser-radiation detection based on intensity interferometry: evaluation of signal and noise},
  journal = {Journal of the Optical Society of America A},
  year = {2026},
  volume = {43},
  number = {5},
  pages = {745},
  doi = {10.1364/josaa.579005}
}
Kostenlos starten →