EUVIMEDEUVIMED entdecken
Crossref

Interscan time influence on effective in-vivo choriocapillaris imaging using a scanning distortion-corrected high-speed OCT system

Mohammad Shahidul Islam, Myeong Jin Ju

Biomedical Optics Express · 01.11.2026 · 17 (11) · 6006

DOI: 10.1364/boe.612143 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 29.10.2026. Verfasst von Mohammad Shahidul Islam und 1 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Gefördert von: Canadian Institutes of Health Research, Natural Sciences and Engineering Research Council of Canada, Canadian Cancer Society.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Although shorter interscan time, when balanced with adequate transverse sampling, can effectively resolve the choriocapillaris (CC) microvascular pattern, the optimized lower temporal range that maintains sufficient OCT-angiography (OCTA) contrast and clear CC delineation has not been established. High-speed bidirectional scanning can provide access to shorter interscan time conditions while preserving dense sampling; however, direction-dependent mismatch between forward and backward scans can introduce decorrelation artifact and obscure the true influence of interscan time. In this study, we investigated the optimum effective interscan time range for in-vivo CC imaging using a distortion-corrected bidirectional 1.6 MHz Fourier domain mode-locked laser (FDML) swept-source OCT system. Densely sampled volumes were acquired, and the corrected dataset was used to investigate spatially varying and uniform interscan time conditions. In the adjacent-pair conditions, the region with more distinctly resolved CC texture shifted according to the interscan time gradient, allowing the optimized lower temporal range for CC visualization to be identified. The number of repeated B-scans was also reduced to further determine whether the identified temporal range could be retained within a faster acquisition, and the resulting three BM-scan protocol preserved clear CC microvascular texture when this range was incorporated. Our findings demonstrate that effective interscan time is a critical parameter for resolving the CC microvasculature, and that maintaining the optimized temporal range allows clear CC visualization in a high-speed OCT system.

Förderung

  • Canadian Institutes of Health Research
  • Natural Sciences and Engineering Research Council of Canada
  • Canadian Cancer Society

Zitieren

APA

Islam, M. S., & Ju, M. J. (2026). Interscan time influence on effective in-vivo choriocapillaris imaging using a scanning distortion-corrected high-speed OCT system. Biomedical Optics Express, 17(11), 6006. https://doi.org/10.1364/boe.612143

Vancouver

Islam MS, Ju MJ. Interscan time influence on effective in-vivo choriocapillaris imaging using a scanning distortion-corrected high-speed OCT system. Biomedical Optics Express. 2026;17(11):6006. doi:10.1364/boe.612143

BibTeX
@article{Islam2026,
  author = {Islam, Mohammad Shahidul and Ju, Myeong Jin},
  title = {Interscan time influence on effective in-vivo choriocapillaris imaging using a scanning distortion-corrected high-speed OCT system},
  journal = {Biomedical Optics Express},
  year = {2026},
  volume = {17},
  number = {11},
  pages = {6006},
  doi = {10.1364/boe.612143}
}
Kostenlos starten →