Fabrication of end-coated fibre-optic ultrasound transmitters
Biomedical Optics Express · 01.10.2026 · 17 (10) · 5048
DOI: 10.1364/boe.608606 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 08.09.2026. Verfasst von Semyon Bodian und 7 weiteren Autor:innen. Beteiligte Einrichtung: UCL Hawkes Institute, University College London, London, UK. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, Engineering and Physical Sciences Research Council, Royal Academy of Engineering.
Abstract (Originalsprache)
Obliquely emitting fibre-optic optical ultrasound (OpUS) probes show strong potential for guiding minimally invasive procedures, but the imprecise coating methods used to date deposit excess coating along the side of the fibre, which has been suspected to cause imaging artefacts. In this study, we aimed to confirm the source of these artefacts and to introduce an alternative coating method. Optical fibres cleaved at 40° were coated either by conventional dip-coating (DC) or by a new dip-transfer (DT) method, where the curvature of coating droplets allows for accurate alignment of angle-cleaved end-faces. To demonstrate the advantage of DT over DC deposition, fibre-optic ultrasound sources were fabricated using both methods and thoroughly characterised using planar and cylindrical acoustic field scans. Furthermore, a source fabricated with each method was assembled into a fibre-optic OpUS imaging probe and used to image a controlled phantom. DT transmitters generated significantly higher ultrasound pressures than DC transmitters (1.64 ± 0.14 MPa vs 0.53 ± 0.22 MPa, p < 0.05), with comparable mean bandwidths (24.7 ± 1.6 MHz vs 17.3 ± 6.9 MHz) with significantly lower variability. Cylindrical field scans revealed that DC transmitters exhibited strong secondary acoustic lobes (20% of primary beam amplitude), whereas sources fabricated with the DT method did not generate detectable spurious emissions. Imaging trials confirmed that coating of the fibre sides is the primary source of artefacts in obliquely emitting OpUS probes. The DT method effectively eliminates these artefacts while simultaneously enhancing acoustic performance. The higher acoustic performance and the absence of spurious emissions and their associated image artefacts will further advance the quality of OpUS image guidance of minimally invasive interventions. Furthermore, this study reinforces the need for specialised coating methods for obliquely-viewing OpUS probes and highlights the importance the coating coverage in determining image quality.
Autor:innen und Institutionen
- UCL Hawkes Institute, University College London, London, UK.
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK.
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia, Canada.
ORCID-Profile: Semyon Bodian, Shaoyan Zhang, Richard J Colchester, Erwin J Alles
Förderung
- Wellcome Trust
- Engineering and Physical Sciences Research Council
- Royal Academy of Engineering
- European Research Council
Zitieren
APA
Bodian, S., Zhang, S., Nassren, N., Zhang, E. Z., Beard, P. C., Colchester, R. J., Desjardins, A. E., & Alles, E. J. (2026). Fabrication of end-coated fibre-optic ultrasound transmitters. Biomedical Optics Express, 17(10), 5048. https://doi.org/10.1364/boe.608606
Vancouver
Bodian S, Zhang S, Nassren N, Zhang EZ, Beard PC, Colchester RJ, et al. Fabrication of end-coated fibre-optic ultrasound transmitters. Biomedical Optics Express. 2026;17(10):5048. doi:10.1364/boe.608606
BibTeX
@article{Bodian2026,
author = {Bodian, Semyon and Zhang, Shaoyan and Nassren, Nyma and Zhang, Edward Z and Beard, Paul C and Colchester, Richard J and Desjardins, Adrien E and Alles, Erwin J},
title = {Fabrication of end-coated fibre-optic ultrasound transmitters},
journal = {Biomedical Optics Express},
year = {2026},
volume = {17},
number = {10},
pages = {5048},
doi = {10.1364/boe.608606}
}
EUVIMED