Double-pulse laser capture microdissection with a needle beam for reduced collateral damage in biological samples
Biomedical Optics Express · 01.07.2026 · 17 (7) · 3617
DOI: 10.1364/boe.604195 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 15.06.2026. Verfasst von Simo Tian und 7 weiteren Autor:innen. Beteiligte Einrichtung: Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan 4300…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Brain Science and Brain-like Intelligence Technology-National Science and Technology Major Project, Science and Technology Talent Innovation Project in Hainan Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Laser capture microdissection (LCM) enables spatially selective isolation of cells and tissues, but precise cutting in thick biological samples is constrained by the limited axial interaction range of Gaussian beams and the side-lobe effects of nondiffractive beams. Here, we propose double-pulse laser capture microdissection with a needle beam (DPLM-NB) for thick biological samples. A 60-μm-long needle beam provides an extended axial interaction range, while double-pulse delay control improves energy localization and cutting selectivity. Numerical simulations show that pre-excitation by the first pulse enhances energy coupling in the main-lobe region and weakens the side-lobe-associated response. In 30-μm-thick frozen mouse brain sections, the method reduces the cutting width from 6.75 to 2.47 μm and the threshold energy density from 5.02 to 1.96 J/cm 2 compared with single-pulse Gaussian-beam cutting. At delays of 1.0–1.3 ns, it achieves an average cutting width of 2.63 μm and threshold energy density of 1.85 J/cm 2 with reduced collateral damage, enabling precise microdissection for downstream omics analysis.
Autor:innen und Institutionen
- Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan 430074, China.
- State Key Laboratory of Digital Medical Engineering, Key Laboratory of Biomedical Engineering of Hainan Province, School of Biomedical Engineering, Hainan University, Haikou 570228, China.
- HUST-Suzhou Institute for Brainsmatics, JITRI, Suzhou 215123, China.
ORCID-Profile: Hui Gong, Qingming Luo, Xiaoquan Yang
Förderung
- Brain Science and Brain-like Intelligence Technology-National Science and Technology Major Project
- Science and Technology Talent Innovation Project in Hainan Province
- National Natural Science Foundation of China
- Fund of Key Laboratory of Biomedical Engineering of Hainan Province
- the 111 Project
Zitieren
APA
Tian, S., He, Z., Li, D., Shang, F., Li, X., Gong, H., Luo, Q., & Yang, X. (2026). Double-pulse laser capture microdissection with a needle beam for reduced collateral damage in biological samples. Biomedical Optics Express, 17(7), 3617. https://doi.org/10.1364/boe.604195
Vancouver
Tian S, He Z, Li D, Shang F, Li X, Gong H, et al. Double-pulse laser capture microdissection with a needle beam for reduced collateral damage in biological samples. Biomedical Optics Express. 2026;17(7):3617. doi:10.1364/boe.604195
BibTeX
@article{Tian2026,
author = {Tian, Simo and He, Zhiguo and Li, Dongshu and Shang, Fengqin and Li, Xiangning and Gong, Hui and Luo, Qingming and Yang, Xiaoquan},
title = {Double-pulse laser capture microdissection with a needle beam for reduced collateral damage in biological samples},
journal = {Biomedical Optics Express},
year = {2026},
volume = {17},
number = {7},
pages = {3617},
doi = {10.1364/boe.604195}
}
EUVIMED