Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 10.08.2026. Verfasst von Lizheng Hou und 3 weiteren Autor:innen. Beteiligte Einrichtung: Hebei Key Laboratory of Optoelectronic Information and Geo-detection Technology, Hebei GEO University, Shijiazhuang 050031, China. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Hebei Provincial Department of Education, S&T Program of Hebei.
Abstract (Originalsprache)
We present a simulation-driven framework that jointly optimizes probe geometry, source–detector separation, and dual-wavelength configuration for wearable continuous-wave functional near-infrared spectroscopy. Five candidate layouts built around a non-collinear 2 × 3 matrix probe were evaluated on a Monte Carlo eXtreme platform using cortical-shell contribution ratio and detector-fluence metrics, followed by Cramér–Rao lower bound (CRLB) analysis of all ten wavelength pairs drawn from {660, 760, 810, 850, 904} nm, with tissue absorption including an explicit water term and pairs ranked directly by total estimation uncertainty (σtotal) rather than a weighted composite score. The two-dimensional cross-coverage geometry with the 660/904 nm pair yielded the lowest total estimation uncertainty (σtotal = 0.0490 μM, cond(A) = 1.50) and remained stable under pathlength, noise-model, and fluence-cutoff perturbations. A geometry-defined motor-cortex region of interest on a public finger-tapping dataset provided pipeline validation, a Colin27 anatomical-atlas simulation supported the directional robustness of the geometry result, and a four-channel prototype demonstrated hardware feasibility. The principal contribution is a reproducible simulation–statistics–validation methodology; the 660/904 nm configuration is the framework’s model-based prediction under the present tissue model, to be confirmed by future in-vivo wavelength comparison.
Autor:innen und Institutionen
- Hebei Key Laboratory of Optoelectronic Information and Geo-detection Technology, Hebei GEO University, Shijiazhuang 050031, China.
- Hebei GEO University, Shijiazhuang 050031, China.
ORCID-Profile: Lizheng Hou
Förderung
- Hebei Provincial Department of Education
- S&T Program of Hebei
Zitieren
APA
Hou, L., Pan, Y., Li, S., & Zheng, Y. (2026). Simulation-driven probe design and dual-wavelength optimization for wearable cerebral oxygenation monitoring. Biomedical Optics Express, 17(9), 4568. https://doi.org/10.1364/boe.603153
Vancouver
Hou L, Pan Y, Li S, Zheng Y. Simulation-driven probe design and dual-wavelength optimization for wearable cerebral oxygenation monitoring. Biomedical Optics Express. 2026;17(9):4568. doi:10.1364/boe.603153
BibTeX
@article{Hou2026,
author = {Hou, Lizheng and Pan, Yihan and Li, Shuang and Zheng, Yibo},
title = {Simulation-driven probe design and dual-wavelength optimization for wearable cerebral oxygenation monitoring},
journal = {Biomedical Optics Express},
year = {2026},
volume = {17},
number = {9},
pages = {4568},
doi = {10.1364/boe.603153}
}
EUVIMED