EUVIMEDEUVIMED entdecken
Open Access

Spiral scan and cylindrical deconvolution to maximize image volume and contrast of multiphoton GRIN microendoscopy

Risa Kitamura iD, Pin-Chun Liao, Cheng-Han Wang, Ting-Chen Chang, Yi-Cheng Chiang, Shih-Kuo Chen, Shi-Wei Chu iD

Biomedical Optics Express · 01.08.2026 · 17 (8) · 4342

DOI: 10.1364/boe.597471 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 24.07.2026. Verfasst von Risa Kitamura und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Psychology, National Taiwan University, Taipei, 10617, Taiwan. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Science and Technology Council, Ministry of Education.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optical microscopy provides sub-cellular and high-speed imaging to capture neuron dynamics in a living brain, but its penetration depth is limited by tissue scattering. Multiphoton excitation improves the depth to over 1 mm, while combining with a gradient refractive index (GRIN) lens enables centimeter penetration with minimal invasiveness. However, the system performance is compromised due to the intrinsic optical aberrations of GRIN lenses, which severely reduce the contrast, spatial resolution, and effective field of view (FoV). To address this issue, we developed a 3D aberration correction approach for GRIN lenses by combining spiral scanning with cylindrical deconvolution. This method leverages the cylindrical symmetry of GRIN-induced aberrations and incorporates the spatially varying point-spread function (PSF) across the imaging volume. Radially adaptive excitation implemented through spiral scanning expanded the usable FoV diameter by nearly 2-fold and achieved 30- and 10-fold improvement, respectively, in peripheral signal intensity and signal-to-noise ratio (SNR) compared to conventional raster scanning with uniform excitation, while cylindrical deconvolution improved spatial resolution by up to 3.5-fold. We further validated this method through 3D imaging of neuronal structures, demonstrating enhanced effective volume size and a 2-fold improvement in neuronal SNR. These results indicate that the spiral scanning and algorithm-augmented GRIN 2PF system is promising toward resolving structure/functional connectomics in deep brain regions.

Autor:innen und Institutionen

  • Department of Psychology, National Taiwan University, Taipei, 10617, Taiwan.
  • Department of Physics, National Taiwan University, Taipei, 10617, Taiwan.
  • Department of Life Science, National Taiwan University, Taipei, 10617, Taiwan.
  • Neurobiology and Cognitive Science Center, National Taiwan University, Taipei, 10617, Taiwan.
  • Center for Biotechnology, National Taiwan University, Taipei, 10617, Taiwan.
  • Brain Research Center, National Tsing Hua University, Hsinchu, 30013, Taiwan.

ORCID-Profile: Risa Kitamura, Shi-Wei Chu

Förderung

  • National Science and Technology Council
  • Ministry of Education

Zitieren

APA

Kitamura, R., Liao, P. C., Wang, C. H., Chang, T. C., Chiang, Y. C., Chen, S. K., & Chu, S. W. (2026). Spiral scan and cylindrical deconvolution to maximize image volume and contrast of multiphoton GRIN microendoscopy. Biomedical Optics Express, 17(8), 4342. https://doi.org/10.1364/boe.597471

Vancouver

Kitamura R, Liao PC, Wang CH, Chang TC, Chiang YC, Chen SK, et al. Spiral scan and cylindrical deconvolution to maximize image volume and contrast of multiphoton GRIN microendoscopy. Biomedical Optics Express. 2026;17(8):4342. doi:10.1364/boe.597471

BibTeX
@article{Kitamura2026,
  author = {Kitamura, Risa and Liao, Pin-Chun and Wang, Cheng-Han and Chang, Ting-Chen and Chiang, Yi-Cheng and Chen, Shih-Kuo and Chu, Shi-Wei},
  title = {Spiral scan and cylindrical deconvolution to maximize image volume and contrast of multiphoton GRIN microendoscopy},
  journal = {Biomedical Optics Express},
  year = {2026},
  volume = {17},
  number = {8},
  pages = {4342},
  doi = {10.1364/boe.597471}
}