Multi-modal and inter-device retinal OCT registration via learning-based feature correspondence
Biomedical Optics Express · 01.05.2026 · 17 (5) · 2481
DOI: 10.1364/boe.596169 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 17.04.2026. Verfasst von Tiffany Tse und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Faculty of Medicine and Applied Science, University of British Columbia, Vancouver, BC V6T 1Z3, Canada. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Natural Sciences and Engineering Research Council of Canada, Canadian Institutes of Health Research, Canadian Cancer Society.
Abstract (Originalsprache)
Accurate registration of widefield OCT volumes is essential in ophthalmology to compensate for motion artifacts, enhance image quality, and enable precise delineation of retinal structures for both single- and multi-modal imaging. We present a learning-guided, feature-based 3D registration framework that combines advanced keypoint detection, transformer-based feature matching, and non-rigid warping to align multiple OCT volumes across repeated acquisitions, encompassing both healthy and diseased cases. Our approach supports both longitudinal, inter-device, and multi-modal registration, including alignment between OCT and standard color fundus images. At a single time point, registered volumes are averaged to produce high-quality, motion-free representations with enhanced signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and high structural similarity index (SSIM), while the derived transformations can be applied to polarization-resolved signals to extract additional functional information. Quantitative evaluation demonstrates substantial improvements in SNR and CNR, with a mean 3D SSIM exceeding 0.97 for single modality cases, and landmark-based target registration error reduced to 2 pixels for multi-modal cases, indicating precise geometric alignment. Qualitatively, the method reduces speckle noise, improves layer connectivity, and strengthens retinal vascular contrast, providing clinicians with a more reliable baseline for interpretation. This framework is versatile, applicable to multi-modal OCT analysis, and enables downstream tasks such as segmentation, quantitative assessment, and longitudinal studies, offering significant potential for enhanced retinal disease monitoring and clinical decision-making.
Autor:innen und Institutionen
- School of Biomedical Engineering, Faculty of Medicine and Applied Science, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.
- Department of Computer Science, University of British Columbia, Vancouver, BC, Canada.
- Faculty of Medicine, University of Calgary, Calgary, AB, Canada.
- Department of Ophthalmology and Visual Sciences, University of British Columbia, Vancouver, BC, Canada.
ORCID-Profile: Tiffany Tse, Michelle Pham, Myeong Jin Ju
Förderung
- Natural Sciences and Engineering Research Council of Canada
- Canadian Institutes of Health Research
- Canadian Cancer Society
Zitieren
APA
Tse, T., Xie, Z., Shahidul Islam, M., Pham, M., Navajas, E. V., Mammo, Z., & Ju, M. J. (2026). Multi-modal and inter-device retinal OCT registration via learning-based feature correspondence. Biomedical Optics Express, 17(5), 2481. https://doi.org/10.1364/boe.596169
Vancouver
Tse T, Xie Z, Shahidul Islam M, Pham M, Navajas EV, Mammo Z, et al. Multi-modal and inter-device retinal OCT registration via learning-based feature correspondence. Biomedical Optics Express. 2026;17(5):2481. doi:10.1364/boe.596169
BibTeX
@article{Tse2026,
author = {Tse, Tiffany and Xie, Zhuoting and Shahidul Islam, Mohammad and Pham, Michelle and Navajas, Eduardo V and Mammo, Zaid and Ju, Myeong Jin},
title = {Multi-modal and inter-device retinal OCT registration via learning-based feature correspondence},
journal = {Biomedical Optics Express},
year = {2026},
volume = {17},
number = {5},
pages = {2481},
doi = {10.1364/boe.596169}
}
EUVIMED