EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Proto-clinical optoretinography dependence on temporal and spatial resolution

Arman Athwal iD, Ringo Ng, Ayoub Faraji, Yifan Jian, Jem Love, Thomas Smart, Mohammad Shahidul Islam, Myeong Jin Ju iD, Marinko V Sarunic

Biomedical Optics Express · 01.07.2026 · 17 (7) · 3525

DOI: 10.1364/boe.596045 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 10.06.2026. Verfasst von Arman Athwal und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optoretinography (ORG) enables non-invasive measurement of stimulus-evoked photoreceptor deformation using phase-sensitive optical coherence tomography (OCT). In this study, we evaluated how lateral resolution, acquisition speed, and spatial and inter-trial averaging influence velocity-based phase ORG measured with a raster-scanning spectral-domain OCT platform configured to resemble clinically realistic hardware. Seven healthy eyes were imaged while varying beam diameter (1.6–4.8 mm), B-scan rate (400–800 Hz), and averaging strategies. The characteristic biphasic response, a rapid contraction followed by slower elongation, was consistently observed across all conditions. Increasing NA improved structural cone visibility but did not proportionally enhance averaged ORG metrics, while moderate NA often yielded more stable signals. Higher acquisition speeds sharpened the measured contraction dynamics but reduced the signal-to-noise ratio due to increased phase noise. Both spatial and trial averaging substantially improved SNR. These findings demonstrate that repeatable phase-based ORGs can be achieved without cellular resolution or ultrahigh scan rates, and provide practical guidance for implementing proto-clinical ORG on conventional OCT systems.

Autor:innen und Institutionen

  • Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom.
  • Casey Eye Institute, Oregon Health & Science University, Portland, OR 97239, USA.
  • Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR 97239, USA.
  • Institute of Ophthalmology, University College London, London EC1V 9EL, United Kingdom.
  • School of Biomedical Engineering, University of British Columbia, Vancouver, British Columbia V6T 1Z3, Canada.
  • Department of Ophthalmology & Visual Sciences, University of British Columbia, Vancouver, British Columbia V5Z 3N9, Canada.

ORCID-Profile: Arman Athwal, Myeong Jin Ju

Zitieren

APA

Athwal, A., Ng, R., Faraji, A., Jian, Y., Love, J., Smart, T., Islam, M. S., Ju, M. J., & Sarunic, M. V. (2026). Proto-clinical optoretinography dependence on temporal and spatial resolution. Biomedical Optics Express, 17(7), 3525. https://doi.org/10.1364/boe.596045

Vancouver

Athwal A, Ng R, Faraji A, Jian Y, Love J, Smart T, et al. Proto-clinical optoretinography dependence on temporal and spatial resolution. Biomedical Optics Express. 2026;17(7):3525. doi:10.1364/boe.596045

BibTeX
@article{Athwal2026,
  author = {Athwal, Arman and Ng, Ringo and Faraji, Ayoub and Jian, Yifan and Love, Jem and Smart, Thomas and Islam, Mohammad Shahidul and Ju, Myeong Jin and Sarunic, Marinko V},
  title = {Proto-clinical optoretinography dependence on temporal and spatial resolution},
  journal = {Biomedical Optics Express},
  year = {2026},
  volume = {17},
  number = {7},
  pages = {3525},
  doi = {10.1364/boe.596045}
}
Kostenlos starten →