Sensitivity factors for diffuse optics – derivation of equations for finite changes
Biomedical Optics Express · 01.08.2026 · 17 (8) · 4455
DOI: 10.1364/boe.591980 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 29.07.2026. Verfasst von Aleh Sudakou und 3 weiteren Autor:innen. Beteiligte Einrichtung: Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland. Die Arbeit nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Centre, Institute of Biocybernetics and Biomedical Engineering.
Abstract (Originalsprache)
We present analytical equations for time-resolved signals in diffuse optics and their sensitivity factors in homogeneous media, derived from perturbation-based equations valid for infinitesimal changes and then extended to finite changes in optical properties. Time-resolved optical measurements are becoming increasingly available due to technological advancements, expanding their use in various techniques such as near-infrared spectroscopy (NIRS). These measurements acquire distributions of times of flight (DTOF) of photons, and the measurands considered in this study are attenuation ( A ), mean time of flight ( m 1 ), and variance ( V ) of the DTOF. Established methods for recovering changes in the absorption coefficient (Δ μ a ) from Δ A , Δ m 1 , or Δ V use perturbation-based sensitivity factors, which are valid for infinitesimal changes. We derived sensitivity factor equations that relate Δ A , Δ m 1 , and Δ V to finite (including large) changes in absorption (Δ μ a ), reduced scattering coefficient (Δ μ s ′ ), and source-detector distance (Δ r ). The derivations rely on solutions of the diffusion equation (DE) for homogeneous infinite (IM) and semi-infinite (SM) media within the diffusion approximation ( μ s ′ ≫ μ a ), without introducing additional assumptions. We also present analytical equations for the modified Beer–Lambert law (MBLL) that are valid for finite Δ μ a in IM and SM, which can be directly applied in continuous-wave NIRS data analysis. Sensitivity factors and the MBLL require knowledge of the baseline optical properties and the differential pathlength factor ( DPF ), and we assessed how errors in these parameters affect the recovered Δ μ a . We also assessed cross-talk, in which scattering changes Δ μ s ′ lead to spuriously recovered absorption changes Δ μ a , and vice versa. The proposed framework can be used to improve the accuracy of methods for estimating changes in optical properties.
Autor:innen und Institutionen
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland.
ORCID-Profile: Aleh Sudakou, Stanislaw Wojtkiewicz, Adam Liebert
Förderung
- National Science Centre
- Institute of Biocybernetics and Biomedical Engineering
Zitieren
APA
Sudakou, A., Wojtkiewicz, S., Maniewski, R., & Liebert, A. (2026). Sensitivity factors for diffuse optics – derivation of equations for finite changes. Biomedical Optics Express, 17(8), 4455. https://doi.org/10.1364/boe.591980
Vancouver
Sudakou A, Wojtkiewicz S, Maniewski R, Liebert A. Sensitivity factors for diffuse optics – derivation of equations for finite changes. Biomedical Optics Express. 2026;17(8):4455. doi:10.1364/boe.591980
BibTeX
@article{Sudakou2026,
author = {Sudakou, Aleh and Wojtkiewicz, Stanislaw and Maniewski, Roman and Liebert, Adam},
title = {Sensitivity factors for diffuse optics – derivation of equations for finite changes},
journal = {Biomedical Optics Express},
year = {2026},
volume = {17},
number = {8},
pages = {4455},
doi = {10.1364/boe.591980}
}
EUVIMED