EUVIMEDEUVIMED entdecken
Open Access

Instrument-integrated optical coherence tomography for quantitative assessment of tissue alteration in retinal endolaser photocoagulation

Dongyue Wu iD, Max Mai Tobon, Florian Lux iD, Eleonora Tagliabue, Philipp Matten iD, Çağlar Ataman iD

Biomedical Optics Express · 01.06.2026 · 17 (6) · 3256

DOI: 10.1364/boe.587627 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 29.05.2026. Verfasst von Dongyue Wu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Microsystems Engineering, University of Freiburg, Germany. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Carl Zeiss AG.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Retinal endolaser photocoagulation (REPC) is a common vitreoretinal procedure, yet quantitative and intraoperative assessment of treatment outcomes remains challenging with microscopic imaging or conventional microscope-integrated optical coherence tomography (miOCT) systems. In this work, we evaluate a novel endolaser probe with instrument-integrated optical coherence tomography (iiOCT) for tissue monitoring in retinal endolaser photocoagulation (REPC) procedures. Retinal tissue changes in ex vivo porcine eyes were quantified from iiOCT M-scans (consecutive A-scans acquired over time), enabling both structural and phase-sensitive characterization of laser-induced responses. We also developed mixed-effect models incorporating iiOCT-derived metrics to predict reference dosimetry metrics from microscopic images and miOCT C-scans. The ordinal model reliably classified lesion visibility (accuracy = 0.884), outperforming a laser-parameters-only model. The linear model effectively predicted lesion size (average R 2 = 0.87), with the inclusion of the iiOCT-derived M-metric improving R 2 by approximately 8.3%. This proposed system bridges the gap between miOCT- and iiOCT-based dosimetry and establishes a foundation for real-time intraoperative feedback to improve the safety and efficacy of retinal endolaser surgery.

Autor:innen und Institutionen

  • Department of Microsystems Engineering, University of Freiburg, Germany.
  • Corporate Research & Technology, Carl Zeiss AG, Eggenstein-Leopoldshafen, Germany.

ORCID-Profile: Dongyue Wu, Florian Lux, Philipp Matten, Çağlar Ataman

Förderung

  • Carl Zeiss AG

Zitieren

APA

Wu, D., Mai Tobon, M., Lux, F., Tagliabue, E., Matten, P., & Ataman, Ç. (2026). Instrument-integrated optical coherence tomography for quantitative assessment of tissue alteration in retinal endolaser photocoagulation. Biomedical Optics Express, 17(6), 3256. https://doi.org/10.1364/boe.587627

Vancouver

Wu D, Mai Tobon M, Lux F, Tagliabue E, Matten P, Ataman Ç. Instrument-integrated optical coherence tomography for quantitative assessment of tissue alteration in retinal endolaser photocoagulation. Biomedical Optics Express. 2026;17(6):3256. doi:10.1364/boe.587627

BibTeX
@article{Wu2026,
  author = {Wu, Dongyue and Mai Tobon, Max and Lux, Florian and Tagliabue, Eleonora and Matten, Philipp and Ataman, Çağlar},
  title = {Instrument-integrated optical coherence tomography for quantitative assessment of tissue alteration in retinal endolaser photocoagulation},
  journal = {Biomedical Optics Express},
  year = {2026},
  volume = {17},
  number = {6},
  pages = {3256},
  doi = {10.1364/boe.587627}
}
Kostenlos starten →