EUVIMEDEUVIMED entdecken
Open Access

Miniaturized handheld Raman imager based on 2D MEMS scanning for non-destructive analysis of thermally sensitive samples

Yuhe Zheng iD, Taotao Mu iD

Biomedical Optics Express · 01.05.2026 · 17 (5) · 2312

DOI: 10.1364/boe.587464 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 10.04.2026. Verfasst von Yuhe Zheng und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Instrumentation Science and Opto-electronics Engineering, Beijing Information Science and Technology University, Beijing 100192, China. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: 2022 Beijing Municipal Universities Outstanding Young Talent Cultivation Program, Beijing Municipal Science and Technology Rising Star Program Cross-Collaboration Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-power-density laser focusing can enhance Raman throughput but often causes thermal degradation in dark or heat-sensitive samples, leading to fluorescence background, peak distortion, or even material combustion. Here, we present a handheld Raman imaging system incorporating a two-dimensional micro-electro-mechanical (2D MEMS) mirror that enables programmable spatial scanning of the excitation beam. By distributing laser energy temporally and spatially, the proposed system effectively suppresses photothermal damage while preserving spectral fidelity. Replacing conventional 2D nano-positioning stages with a MEMS scanning module enables, to the best of our knowledge, the first handheld Raman device capable of performing full-field (i.e., simultaneous imaging of the entire field of view) chemical imaging. Experiments on four dark or thermally sensitive substances, including potassium permanganate and Sudan III, demonstrate significant reductions in localized power density, improved signal-to-noise ratio (SNR), and complete elimination of sample damage. Point array scan imaging of a composite pharmaceutical tablet further visualizes the spatial distribution of its chemical components, confirming the system’s practical utility for non-destructive, field-deployable Raman imaging. The integration of MEMS scanning technology addresses long-standing limitations of conventional Raman systems and aligns with the growing demand for miniaturized, portable optical sensors.

Autor:innen und Institutionen

  • School of Instrumentation Science and Opto-electronics Engineering, Beijing Information Science and Technology University, Beijing 100192, China.

ORCID-Profile: Yuhe Zheng, Taotao Mu

Förderung

  • 2022 Beijing Municipal Universities Outstanding Young Talent Cultivation Program
  • Beijing Municipal Science and Technology Rising Star Program Cross-Collaboration Project

Zitieren

APA

Zheng, Y., & Mu, T. (2026). Miniaturized handheld Raman imager based on 2D MEMS scanning for non-destructive analysis of thermally sensitive samples. Biomedical Optics Express, 17(5), 2312. https://doi.org/10.1364/boe.587464

Vancouver

Zheng Y, Mu T. Miniaturized handheld Raman imager based on 2D MEMS scanning for non-destructive analysis of thermally sensitive samples. Biomedical Optics Express. 2026;17(5):2312. doi:10.1364/boe.587464

BibTeX
@article{Zheng2026,
  author = {Zheng, Yuhe and Mu, Taotao},
  title = {Miniaturized handheld Raman imager based on 2D MEMS scanning for non-destructive analysis of thermally sensitive samples},
  journal = {Biomedical Optics Express},
  year = {2026},
  volume = {17},
  number = {5},
  pages = {2312},
  doi = {10.1364/boe.587464}
}
Kostenlos starten →